    PKGR-PSD003B-EN_09102025

    ) Dry bulb control standard with economizer.(f) Downflow only.(g) Low Ambient cooling requires crankcase heater (BAYCCHT-A).(h) BAYCOVR112,118A will not cover 18-in. square-to-round applications.(i) Must be selected per unit and heater model. Optional Equipment Listing 6 PKGR-PSD003B-EN Product
  • Media type icon

    12134357_B_07192022

    Document Title:IPAK 1 POWER SCHEMATIC 20-75T REFRIGERATION POWER INDUCTION MOTORS, STANDARD AMBIENT
    Publication Type:Wiring Diagram or Manual
    Publication Date:2022-07-19
    LEGENDREF DES DESCRIPTION LINE NO 1F10 FUSEBLOCK - CONDENSER FAN CIRCUIT 1 951F11 FUSEBLOCK - CONDENSER FAN CIRCUIT 2 1081F30 FUSEBLOCK - PHASE MONITOR 651K1 PHASE MONITOR 65 1QA1 CIRCUIT BREAKER - COMPRESSOR 1A 781QA2 CIRCUIT BREAKER - COMPRESSOR 1B 821QA3 CIRCUIT BREAKER - COMPRESSOR 1C 851QA4
  • Media type icon

    18-HD25D21-2_03012006

    Document Title:Trane TCONT602AF22MA Programmable Comfort Control
    Publication Type:Installation
    Publication Date:2006-03-01
    TCONT602AF22MAProgrammable Comfort Control Installation Instructions 69-1835-1 Pub. No. 18-HD25D21-2 Product ApplicationThis Comfort Control provides electronic control of 24 VAC single-stage and multi-stage heating and cooling systems. System Types (up to 2 heat/2 cool)• Gas, oil or electric heat
  • Media type icon

    RMWG-SVX01C-EN_04012003

    Document Title:TruSense SD Refrigerant Monitor - Sensor Module / Installation Operation Maintenance
    Publication Type:Installation Operation and Maintenance
    Publication Date:2003-04-01
    -perature: 25°C N2 18 RMWG-SVX01C-EN Installation Infrared Photoacoustics Increased industrialization together with a growing concern for human safety and the environment have stimulated the demand for sensitive and reliable methods of detecting trace amounts of gases. The advantages of infrared
  • Media type icon

    18-CD29D1-18-EN_02012019

    Document Title:Installer's Guide - Upflow/ Horizontal, Downflow / Horizontal Gas-Fired, Direct Vent Condensing Furnaces *UH1 & *DH1 Models (*First letter may be "A" or "T")
    Publication Type:Installation
    Publication Date:2019-02-01
    /HORIZONTAL *DH1 18-CD29D1-18-EN © 2019 Trane All Rights Reserved 18-CD29D1-18-EN Installer’s GuideSAFETY SECTION The following safety practices and precautions must be followed during the installation, servicing, and opera-tion of this furnace.1. Use only with the type of gas approved for this fur- nace
  • Media type icon

    12134652_B_02202023

    - COMPRESSOR 1A COIL 3921QA6 CONTACTOR - COMPRESSOR 1A AUX 4171QA7 CONTACTOR - COMPRESSOR 1B COIL 3881QA7 CONTACTOR - COMPRESSOR 1B AUX 4151QA8 CONTACTOR - COMPRESSOR 1C AUX 4071QA9 CONTACTOR - COMPRESSOR 2A AUX 4121QA10 CONTACTOR - COMPRESSOR 2B AUX 4101QA11 CONTACTOR - CONDENSER FAN 1A COIL 4011QA12
  • Media type icon

    5071-0458D_02092017

    Document Title:Schematic Hermetic Centrifugal Liquid Chiller CenTraVac AdaptiView Panel Upgrade UCP-2 with Optional HGBP or FRCL
    Publication Type:Wiring Diagram or Manual
    Publication Date:2017-02-09
    AD AP TIV IEW PA NE LU PG RA DE DA TE :1 0-1 -08 RC EN TR AV AC SC HE MA TIC UC P-2 WIT HO PT ION AL HG BP OR FR CL 18 5 20 1 20 0 19 9 19 8 19 7 19 6 19 5 19 4 19 3 19 2 19 1 19 0 18 9 18 8 18 7 18 6 18 2 18 4 18 3 17 9 18 1 18 0 17 6 17 8 17 7 17 3 17 5 17 4 16 9 17 0 17 2 17 1 16 7 16 6 16 8 16
  • Media type icon

    12134879C_01132025

    Document Title:INTELLICORE CA SCHEMATIC 20-60T CONTROLS
    Publication Type:Wiring Diagram or Manual
    Publication Date:2025-01-13
    PTC Plotter Output LEGENDREF DES DESCRIPTION LINE NO1F1 FUSE - 115VAC TRANSFORMER 631F2 FUSE - 115VAC TRANSFORMER 621QA11 CONTACTOR - CONDENSER FAN 1A 791QA11 CONTACTOR - CONDENSER FAN 1A 821QA12 CONTACTOR - CONDENSER FAN 1B 841QA13 CONTACTOR - CONDENSER FAN 1C 861QA14 CONTACTOR - CONDENSER FAN 2A
  • Media type icon

    18-CH47D1-1A-EN_07022020

    Document Title:Installer's Guide for BAYINDUCER17, BAYINDUCER18, BAYINDUCER19, and BAYINDUCER20
    Publication Type:Installation
    Publication Date:2020-07-29
    cuts made on sheet metal while installing or servicing. Personal injury may result. 18-CH47D1-1A-EN CAUTIONThe IFC is polarity sensitive. The hot leg of the 115 VAC power must be connected to the BLACK field lead. ss WARNINGTHE CABINET MUST HAVE AN UNINTERRUPTED OR UN-BROKEN GROUND ACCORDING TO
  • Media type icon

    23116082_A_08232023

    : MASTER FILE: REVISION DATE: REPLACES: SIMILAR TO: USED BY: CR 23116082 1 A SCHEMATICRTHD WYE DELTA STARTER WEIYING MIAO 28-JULY-2012 AVISOCONDUCTORES DE COBRE! LAS TERMINALES DE LA UNIDAD NOEST OTROS TIPOS DE CONDUCTORES. NO REALIZAR LO ANTEDICHO PUEDEPROVOCAR DA AVISN'UTILISER QUE DES CONDUCTEURS EN