Search Results: 18-CH94D1-1C-EN

Showing 2,151 - 2,160 of 7,189 results

Display results per page.
  • Media type icon

    ACC-SVN213D-EN_03142026

    Document Title:Service Valve Kit Odyssey Split System Cooling and Heat Pump 6 to 25 Ton Units
    Publication Type:Installation
    Publication Date:2026-03-14
    altered equipment by an unqualified person could result in death orserious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. March 2026 ACC-SVN213D-EN Installation GuideService Valve KitOdyssey
  • Media type icon

    SO-SVN009A-EN_08312023

    Document Title:Pumpout Compressor Gasket Change
    Publication Type:Installation
    Publication Date:2023-08-31
    document applies to service offering applications only. Installation Instructions Pumpout Compressor Gasket Change August 2023 SO-SVN009A-EN 1 Warnings, Cautions, and NoticesRead this manual thoroughly before operating or servicing this unit. Safety advisories appear throughout this manual as
  • Media type icon

    88-MACC023-1A-EN_02022022

    Document Title:Installer's Guide 25% Manual Fresh Air Kit MAYOSAH002A
    Publication Type:Installation
    Publication Date:2022-02-02
    88-MACC023-1A-EN 25% Manual Fresh Air KitMAYOSAH002A Installer’s Guide Used with 2 - 3.5 Ton Double Deck Gas Units Only Safety Section WARNING��HAZARDOUS VOLTAGE! Failure to follow this Warning could result in property damage, severe personal injury, or death. Disconnect all electric power
  • Media type icon

    APP-PRC006B-EN_02202024

    14ºF ∆T condenser water ASHRAE GreenGuide10 • 12-20°F ΔT chilled water• 12-18°F ΔT condenser water CoolTools™ Chilled Water Plant Design and Specification Guide, 200011 • 15-18°F ΔT chilled water Kelly and Chan, Optimizing Chilled Water Plants, HPAC Engineering, 199912 • 18°F ΔT chilled water• 14°F
  • Media type icon

    BAS-SVX35C-EN_08152023

    Document Title:TR200 Embedded BACnet
    Publication Type:Installation Operation and Maintenance
    Publication Date:2023-08-15
    Operating InstructionsTR200 Embedded BACnet August 2023 BAS-SVX35C-EN SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific
  • Media type icon

    2309-1969C_02232021

    Document Title:Field Wiring RTUD Paired Condenser
    Publication Type:Wiring Diagram or Manual
    Publication Date:2021-02-23
    C:\Documents and Settings\lbgdw\Desktop˜91969-C Layout1 (1 Release on 1/26/2010 MIN MAX 1 1 #10 101 2 #12 101 2 #14 101 4 #16 101 5 #18 101 8 #20 101 10 #22 10 WIRES PER LUG WIRE SIZE IN-LB LUG TORQUE Release on 1/26/2010 23091969-C.pdf
  • Media type icon

    1213-4305B_03302022

    BOX 10HTB4 TERM BLOCK-ELECTRIC HEAT 5HTR 1A HEATER-ELECTRIC HEAT 12HTR 2A HEATER-ELECTRIC HEAT 18 WARNING DISCONNECT ALL ELECTRIC POWERINCLUDING REMOTE DISCONNECTSAND FOLLOW LOCK OUT AND TAGPROCEDURES BEFORE SERVICING.INSURE THAT ALL MOTORCAPACITORS HAVE DISCHARGEDSTORED VOLTAGE. UNITS WITHVARIABLE
  • Media type icon

    88-MACC024-1A-EN_02022022

    Document Title:Installer's Guide 25% Manual Fresh Air Kit MAYOSAH003A
    Publication Type:Installation
    Publication Date:2022-02-02
    88-MACC024-1A-EN 25% Manual Fresh Air KitMAYOSAH003A Installer’s Guide Used with 4 - 5 Ton Double Deck Gas Units Only Safety Section WARNING��HAZARDOUS VOLTAGE! Failure to follow this Warning could result in property damage, severe personal injury, or death. Disconnect all electric power, including
  • Media type icon

    2311-4628A_03152020

    Document Title:HUV - Trane Furnished Controls
    Publication Type:Wiring Diagram or Manual
    Publication Date:2020-03-15
    : ANGLES =  HOLE DIA = + - CONFORMS TO ASME Y14.5M - 1994 SHEET OF REV  FINISH TRANE 2311-4628 A 1 1 SCHEMATIC; HUV TRANE FURNISHED CONTROLS 480 VOLT, 3 PH, 4-WIRE ELECTRIC HEAT (4 EL) UNIT SIZE 750 - 2000 SPAINHOUR 7-APR-2017 .06 .03 .015 .005 .005 1 RELEASED 11/Apr/2017 18:35:28 GMT
  • Media type icon

    2311-4624A_03152020

    Document Title:HUV - Trane Controls Electric Heat
    Publication Type:Wiring Diagram or Manual
    Publication Date:2020-03-15
    : ANGLES =  HOLE DIA = + - CONFORMS TO ASME Y14.5M - 1994 SHEET OF REV  FINISH TRANE 2311-4624 A 1 1 SCHEMATIC; HUV TRANE CONTROLS - ELECTRIC HEAT (4 EL) 208/240 VOLT, 3 PH, 3-WIRE UNIT SIZE 750, 1000, 1250 SPAINHOUR 7-APR-2017 .06 .03 .015 .005 .005 1 RELEASED 11/Apr/2017 18:35:14 GMT