  • Media type icon

    1213-4826B_10222024

    Document Title:SCHEMATIC; SHEET 4, CONTROLS, ADAPTER BOARD UNIT CONTROLS, SINGLE COMPRESSOR, SINGLE FAN
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-10-22
    LEGENDREF DES DESCRIPTION LINE NOAB MODULE- ADAPTER BOARD 201CC1 CONTACTOR - COMPRESSOR 1 190CC1 (AUX2) CONTACTOR - COMPRESSOR 1 AUX 2 187CUS1 SOLENOID- CMPR 1 UNLOADING 212DTL1 SWITCH- DISCHARGE TEMP LIMIT 1 202HPC1 SWITCH- HIGH PRESSURE CUT OUT 1 199OFC1 CONTACTOR - OUTDOOR FAN 1 182VHR RELAY
  • Media type icon

    18-GJ36D1-1A-EN_07312020

    Document Title:Installer's Guide Compressor Control Module Kit Hyperion and ForeFront Air Handlers
    Publication Type:Installation
    Publication Date:2020-08-11
    installation must comply with NATIONAL, STATE AND LOCAL CODES 18-GJ36D1-1A-EN Fits Models: HyperionTM and ForeFrontTM Air Handlers Section 1. Safety Information �� WARNING!SAFETY HAZARD! This information is intended for use by individuals possessing adequate backgrounds of electrical and mechanical
  • Media type icon

    ACC-SVN31C-EN_04172020

    Document Title:Anti Short Cycle Timer Kit and Time Delay Relay Kit
    Publication Type:Installation
    Publication Date:2020-04-17
    Figure 4. Wire 412 goes to the terminal strip or low voltage leads. Wire 411 splices to the wire to the stage 2 compressor contactor circuit. 6. Replace and secure both access panels and restore power to the unit. April 2020 ACC-SVN31C-EN Installation Instructions Anti Short Cycle Timer Kit and Time
  • Media type icon

    18-BC93D2-1A-EN_03012017

    Document Title:Installer's Guide Thermal Grease Application Instructions Part# SEL01225 1 oz. syringe
    Publication Type:Installation
    Publication Date:2017-03-01
    purposes, the matter should be referred to your installing dealer or local distributor. ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES Installer’s GuideThermal Grease Application Instructions 18-BC93D2-1A-EN Section 1. Safety Only qualified personnel should install
  • Media type icon

    PART-SVN247A-EN_01012021

    Document Title:RuptureGuard 3" Disk Replacement DSK0110 / Installation Instructions
    Publication Type:Installation
    Publication Date:2021-01-01
    an unqualified person could result indeath or serious injury. When working on the equipment, observe all precautions inthe literature and on the tags, stickers, and labels that are attached to theequipment. © 2021 Trane January 2021 PART-SVN247A-EN Installation Instructions RuptureGuard™3-inch Disk
  • Media type icon

    1213-2829D_09302019

    Document Title:INTELLIPAK - SCHEMATIC / LAYOUT; MOD GAS HEAT - 850 MBH
    Publication Type:Wiring Diagram or Manual
    Publication Date:2018-12-13
    - COMBUSTION BLOWER #2 33 3QM20 GAS VALVE #1 83QM21 GAS VALVE #2 103QM22 GAS VALVE #3 283QM23 GAS VALVE #4 303RF1 FILTER - RFI 13S14 SWITCH - SUPPLY AIRFLOW 123S15 SWITCH - HIGH TEMP CUTOUT 73S16 SWITCH - HIGH PRESSURE #1 93S17 SWITCH - HIGH PRESSURE #2 153S18 SWITCH - FLAME ROLL OUT #1 103S19 SWITCH
  • Media type icon

    VRF-SLB043-EN_04272022

    through a broad portfolio of heating, ventilating and air conditioning systems and controls, services, parts and supply. For more information, please visit trane.com or tranetechnologies.com.All trademarks referenced in this document are the trademarks of their respective owners. © 2022 Trane. All Rights Reserved. 04/27/2022 VRF-SLB043-EN
  • Media type icon

    VRF-PRC060C-EN_08042020

    = Multiple GENERATION CODEK = 7th GenerationL = 8th GenerationN = 9th Generation REFRIGERANT4 = R-410a MAJOR CHANGE0 = 1st Gen1 = 2nd Gen2 = 3rd Gen MINOR CHANGEA = 1st GenB = 2nd Gen COIL COATINGN = Standard no coating B = BS Salt Protection All trademarks referenced in this document are the trademarks of their respective owners © 2020 Trane. All Rights Reserved. VRF-PRC060C-EN August 4, 2020
  • Media type icon

    18-HE120D1-1-EN_11012017

    Document Title:Envirowise Supplemtal Heater for use with QF130V Ventilator
    Publication Type:Installation
    Publication Date:2017-11-01
    WITH SMALLER DUCTS THAN RECOMMENDED. INSULATION AROUND THE DUCTS CAN REDUCE ENERGY LOSS AND INHIBIT MOLD GROWTH. Electrical Ratings: EQH400: 120V, 60Hz., 4.8A EQH900: 120V, 60Hz., 9A Installing Contractor: Installation Date: Model Number: 18-HE120D1-1-EN INSTALLATION INSTRUCTIONS CAUTION: MAKE SURE
  • Media type icon

    BAS-SVN076J-EN_06052020

    Document Title:Portable Operator Display for Tracer MP580/581 and AH540/541 / Installation Instructions
    Publication Type:Installation
    Publication Date:2020-06-05
    system. June 2020 BAS-SVN076J-EN Installation Instructions Portable Operator Display For Tracer®MP580/581 and AH540/541 Order Number: 4950 0491 3270 3337 1Warnings, Cautions, and Notices Read this manual thoroughly before operating or servicing this unit.Safety advisories appear throughout this manual as