Search Results: 18-CH37D1-3A-EN

Showing 1,771 - 1,780 of 7,117 results

Display results per page.
  • Media type icon

    ECTV-SLB015-EN_07172020

    Document Title:Refrigerant Pocket Reference
    Publication Type:Sales Brochure
    Publication Date:2020-07-17
    per square footAHU Tons (air) = CFM 350 Run hours per year Conversions from SEER/EER or COP to KW/TONSEER ConversionCOP Conversion KW/TON = 12,000 / (COP * 3413) KW/TON = 12/SEER or EER 24 hourday 7 day wk.4368537667208736 18 hourday 6 day wk.2808345643205616 18 hourday 5 day wk.2340288036004680 12
  • Media type icon

    1213-4861B_05012024

    Document Title:DIAGRAM; COMPONENT LOCATION, GAS, D CABINET,EFLEX, SINGLE COMPRESSOR
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-05-01
    1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 THIS DRAWING IS PROPRIETARYAND SHALL NOT BE COPIED ORITS CONTENTS DISCLOSED TO OUTSIDE PARTIES WITHOUT THEWRITTEN CONSENT OF
  • Media type icon

    22-1810-03_02012009

    Document Title:Trane Direct Vent, Gas Fired Water Boiler with Cast Iron Heat Exchanger
    Publication Type:Product Data
    Publication Date:2009-02-01
    Wiring) L1 NG Circ Pump(Field Supplied) L1 NG 4 12 13 14 15 16 17 18(HV) (LV) T T19 20 L NPOWER 1 2 3 LWCO 5 6 J2(ORANGE) 7 8L N PUMP 9 10 11 J4(BLUE) 21 22 J5(YELLOW) 23 24 System Configuration1. Continuous Pump Operation2. Burner Cycles with Supply Water Thermostatwhen Call from Room Thermostat is
  • Media type icon

    RT-PRC103C-EN_01312025

    . Symbio™ 800 Controls 18 RT-PRC103C-EN SZVAV and VAV OperationNote: SZVAV exceptions are noted in parenthesis. Outside Air ControlOutside Air MeasurementTrane air quality (Traq™) outside air measurement system utilizes velocity pressure sensing rings.Based on unit design CFM, the Symbio™ 800 monitors
  • Media type icon

    PART-SVN261B-EN_09152024

    Document Title:Siemens Actuator Replacement Kit; For Precedent units with Low Leak Economizer FIAECON103AA
    Publication Type:Installation
    Publication Date:2024-09-15
    an unqualified person could result in death orserious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. September 2024 PART-SVN261B-EN Installation InstructionsSiemens Actuator ReplacementKitFor
  • Media type icon

    PART-SVN56A-EN_05012004

    Document Title:Crankcase Heater Installation - TC, YC, and Voyager II
    Publication Type:Installation
    Publication Date:2004-05-01
    PART-SVN56A-EN Models: TC, YC, and Voyager II Table 1. Crankcase heater part number applications Part number Unit size, tons Voltage, Vac KIT09470 15 and 17-1/2 208-230 KIT09471 15 and 17-1/2 460 KIT09472 15 and 17-1/2 575 KIT09467 20 and 25 208-230 KIT09468 20 and 25 460 KIT09469 20 and 25 575
  • Media type icon

    BAS-PRC035D-EN_03302020

    closed OutputsCurrent 0–20 mA @ 16V Voltage 0–16 Vdc @ 20mA Point Total 4 h 2020 BAS-PRC035D-EN Specifications, Agency Compliance, and Dimensions Storage Temperature: -67°F to 203°F (-55°C to 95°C) Relative humidity: 5% to 95% (non-condensing) Operating Temperature: -40°F to 158°F (-40°C to 70°C
  • Media type icon

    12133191B_08262019

    Document Title:Voyager Large Commercial Wiring Diagram
    Publication Type:Wiring Diagram or Manual
    Publication Date:2019-08-26
    18 18 19 3 2 APPROVED 26/Aug/2019 19:37:42 GMT
  • Media type icon

    12133190B_08262019

    Document Title:Voyager Large Commercial Wiring Diagram
    Publication Type:Wiring Diagram or Manual
    Publication Date:2019-08-26
    18 18 19 3 2 APPROVED 26/Aug/2019 19:26:02 GMT
  • Media type icon

    12133189B_08262019

    Document Title:Voyager Large Commercial Wiring Diagram
    Publication Type:Wiring Diagram or Manual
    Publication Date:2019-08-26
    18 18 19 3 2 APPROVED 26/Aug/2019 19:33:16 GMT