Search Results: 18-CH83D1-1B-EN

Showing 1,681 - 1,690 of 7,117 results

Display results per page.
  • Media type icon

    BAS-SVN113C-EN_06012020

    Document Title:Enclosure for Tracer DIN-mounted Controllers (120 VAC) Order Numbers: X13651618010 (Solid Door) X13651619010 (Display-capable Door)
    Publication Type:Installation
    Publication Date:2020-06-01
    by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. © 2020 Trane June 2020 BAS-SVN113C-EN Installation Instructions Enclosure for Tracer DIN
  • Media type icon

    YK-IOM-2_11022000

    Document Title:8 1/2 thru 25 Ton Packaged Gas/Electric - 50 Cycle - Models YKD085C, YKD100C, YKD100B, YKD125C, YKD155B, YKD175C, YKD200B, YKD250B, YKH085C, YKH100C, YKH100B, YKH125C, YKH155B, YKH175C, YKH200B, YKH250B.
    Publication Type:Installation Operation and Maintenance
    Publication Date:2000-11-02
    1BCurb Dimensions - SI - mmFigure UNITS A B C D E F G H J K L M 1B YK*085C, 100C 2064 1170 356 365 438 464 1076 51 46 919 2073 1178 7 INSTALLATIONLocation and Recommendations IMPORTANT: The use of “spreader bars” is requiredwhen hoisting the unit (prevents damage to sides andtop). Top crating can be
  • Media type icon

    ACC-SVN187D-EN_08232024

    Document Title:Oversized Motor Kit - Foundation™ Packaged Rooftop Units
    Publication Type:Installation
    Publication Date:2024-08-23
    the unit disconnect switch, remove the metal plate on the motor, and reverse any two of the motor leads inside the motor.17.Replace any wire ties (removed in Step 5) used to secure the motor leads to the cabinet.18.Replace the access panel. NOTICE Equipment Damage!Proper adjustment of the fan belt
  • Media type icon

    CNT-SVX06A-E4_06012001

    Document Title:Tracer ZN.511 Zone Controller
    Publication Type:Installation Operation and Maintenance
    Publication Date:2001-06-01
    support either of thefollowing configurations: • Water-source heat pumps, one ortwo compressors • 1 heat/1 cool fan coils with two-position valves Note: For information about usingthe Rover service tool, see theRover Installation/ Operation/Programming guide (EMTX-SVX01A-EN). Storage environment If
  • Media type icon

    RT-PRC091F-EN_09152023

    Institute standards (ANSI). Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level. General Data 18 RT-PRC091F-EN Performance DataGross Cooling CapacitiesTable 4. Gross cooling capacities 7.5 tons
  • Media type icon

    RT-SLB051-EN_03042024

    Document Title:Better performance, Great value, More flexibility.
    Publication Type:Sales Brochure
    Publication Date:2024-03-04
    plenum supply fans for easier maintenance • Optional Trane Air Quality (Traq™) for precise outside air control Tonnage Efficiency Tier IEER* 20 20 Ton, eFlex (V) 17.9/17.8 25 25 Ton, Std. Efficiency (S) 15.7 25 Ton, High Efficiency (H) 16.1 / 16.5 25 Ton, eFlex (V) 18 30 30 Ton, Std. Efficiency (S
  • Media type icon

    PART-PRC013A-EN_10312025

    30.35 30.43 30.33 — 140 — — — — 33.05 33.22 33.43 33.53 33.61 33.73 33.71 — 155 — — — — — — 39.49 39.55 39.62 39.72 — — Performance Data 18 PART-PRC013A-EN Table 6. Current (amps) — voltage 460-60-3 (continued) Compressor Cond Temp°F Evaporator Temp °F -25 -10 0 10 20 30 40 45 50 60 70 80 CSHP227
  • Media type icon

    APP-PRC010B-EN_04012025

    APP-PRC010B-EN April 2025 Trane Intelligent VAV SystemsSystem Catalog 2 Trane systems are comprehensive approaches to HVAC system design that support what is best for the building, best for business, and right for the environment. Trane’s Intelligent VAV system is designed to provide superior
  • Media type icon

    BAS-SVN134E-EN_06052020

    Document Title:UUKL Large Enclosure for Tracer DIN-mounted Controllers (120 Vac) Ordering Number: X13651596-01
    Publication Type:Installation
    Publication Date:2020-06-05
    Unit Widths(1 unit = 18 mm) Tracer SC system controller 143.6/5.6 8 Tracer UC400 controller 143.6/5.6 8 Tracer UC600 controller 215.5/8.50 12 Tracer UC800 controller 71.6/2.8 4 Tracer XM30 expansion module 53.6/2.1 3 Tracer XM32 expansion module 71.6/2.8 4 Tracer XM70 expansion module 215.5/8.50
  • Media type icon

    2311-5513B_11022021

    Document Title:Ascend Model ACR, 150 to 300 tons, Unit Field Wiring
    Publication Type:Wiring Diagram or Manual
    Publication Date:2021-11-02
    QUALIFIED TO ACCEPT OTHER TYPES AVISN'UTILISER QUE DES CONDUCTEURS EN CUIVRE! L'UTILISATION DE MATÉRIAUX,AUTRES QUE LE CUIVRE, PEUT ENDOMMAGER L'ÉQUIPEMENT,CELUI-CI N'AYANT PAS ÉTÉ CONÇU OU HOMOLOGUÉ POUR ACCEPTER D'AUTRESTYPES DE CONDUCTEURS. AVISO¡UTILICE CONDUCTORES DE COBRE SOLAMENTE! SI NO UTILIZA