Search Results: 18-CH94D1-1C-EN

Showing 1,661 - 1,670 of 7,136 results

Display results per page.
  • Media type icon

    CNT-SVX04B-EN_06102022

    -pipe heating valve, face/bypass control (continued) 18 CNT-SVX04B-EN Binary Outputs Generic Binary Output/Baseboard Heat OutputTerminals TB4-1 and TB4-2 can be configured for either a generic binary output, or to control baseboard heat.When configured for a generic binary output, the controller does
  • Media type icon

    KIT02067_08012006

    Document Title:KIT02067 KIT; GASKET & O-RING, MODEL E HERMETIC, M DESIGN SEQUENCE NON-ASBESTOS
    Publication Type:Installation
    Publication Date:2006-08-01
    /1992 1 EACHX23130078240 RING; O, NEOPRENE, 1.734 ID X .139 RD, SIZE #224 STK RAW 9/22/1992 1 EACHX22060002000 SHIM; STEEL .010 THK X 3.070 ID 3.95 OD STK RAW 9/22/1992 3 EACHX23040431010 GASKET; TERMINAL PLATE - MODEL E COMPRESSOR, .031 X 7.10 X 10, STK RAW 10/18/1999 1 EACHX23040438010 GASKET
  • Media type icon

    TF-SVX001B-EN _01122026

    Document Title:Thermafit™ Modular Air-Source Multipipe - Model MAS
    Publication Type:Installation Operation and Maintenance
    Publication Date:2026-01-12
    contact with thefloor using manual or mechanical means. Installation Mechanical 18 TF-SVX001B-EN Figure 4. Recommended multipipe rigging Installation Mechanical TF-SVX001B-EN 19 Installation PipingInstall Piping and ExternalComponentsProper support of piping and pipe hangers must considerthe weight
  • Media type icon

    BAS-SVX25C-EN_06152021

    Document Title:TR200 LonWorks® Option Module
    Publication Type:Installation Operation and Maintenance
    Publication Date:2021-06-15
    TR200 LonWorks® Option Module Operating Instructions June 2021 BAS-SVX25C-EN SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific
  • Media type icon

    KIT03018_08012006

    Document Title:KIT03018 KIT; COMPRESSOR MOTOR CHANGEOUT,255/300 TON,STD & LONG SHELL
    Publication Type:Installation
    Publication Date:2006-08-01
    X23130322470 RING;O, 4.609 ID X .139 RD STKRA W 4/22/1996 2 PART-IN-60A LITERATURE; LOCATION OF PARTS FOR KIT03018 STKRAW 10/24/2000 1 X23130322630 RING;O, 7.234 ID X .139 RD STKRA W 12/4/1997 2 X23040440010 GASKET; SERVICE VALVE - MODEL E COMPRESSOR, .031 X 5.12 X 4.38, STKRAW 10/18/1999 2
  • Media type icon

    HEGH-SLB002-EN_05192020

    Document Title:Trane High Efficiency Gas-Fired Unit Heater
    Publication Type:Sales Brochure
    Publication Date:2020-05-19
    Side (Inch) 18 18 18 18 36 36Access Side (Inch) 18 18 18 18 18 18Non access side (Inch) 2 6 6 6 6 6Top (Inch) 2 6 6 6 6 6Bottom (Inch) 2 6 6 6 6 6 † Ratings shown are for unit installations at elevations between 0 and 2,000 feet (0 to 610m). For unit installations in U.S.A. above 2,000 feet (610m
  • Media type icon

    2309-2208U_05042022

    layout2 PRECAUCIÓN ATTENTION CAUTION AVERTISSEMENT ADVERTENCIAWARNING C TRANE RELEASED 04/May/2022 21:18:34 GMT AutoCAD SHX Text FAILURE TO DO SO MAY CAUSE DAMAGE TO THE AutoCAD SHX Text UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT AutoCAD SHX Text N'UTILISER QUE DES CONDUCTEURS EN CUIVRE! AutoCAD SHX
  • Media type icon

    BAS-SVN084E-EN_06092020

    Document Title:Tracer™ XM32 Expansion Module Order Number: X13651563010
    Publication Type:Installation
    Publication Date:2020-06-09
    unsafe NOTICE Indicates a situation that could result in equipment or property-damage only accidents. June 2020 BAS-SVN084E-EN The Tracer XM32 Expansion Module provides additional points when needed for Tracer UC400 and UC600 applications. Each expansion module has a total of four (4) relay outputs. Use
  • Media type icon

    12134655_B_02202023

    Document Title:IPAK2 POWER SCHEMATIC 90-150T AIRFLOW, WITH BYPASS
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-02-20
    /RETURN FAN 386QA39 CONTACTOR - BYPASS RELIEF/RETURN FAN 426TB6 VFD RETURN/RELIEF FAN 38 700A (G/Y) 19A (O)18A (BR) 1A 2A 3A 1A 2A 3A 3L(Y) 3L 2L 2L(O) 2L 1L 1L(BR) 1L 1XP2 16A(BR) 17A(O) O 165A(BR)166A(O)167A(Y) 202BH 202BH(R) 200CU 200CU(W) BROY 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
  • Media type icon

    1213-4888B_08122024

    Document Title:SCHEMATIC; SHEET 1, POWER, DUAL COMPRESSOR, SINGLE CONDENSER FAN, HIGH SCCR
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-08-12
    HACE, PUEDE OCASIONAR DAÑO AL EQUIPO. N'UTILISER QUE DES CONDUCTEURS EN CUIVRE! LES BORNES DE L'UNITÉ NE SONT PAS CONÇUESPOUR RECEVOIR D'AUTRES TYPES DE CONDUCTEURS. L'UTILISATION DE TOUT AUTRE CONDUCTEUR PEUTENDOMMAGER L'ÉQUIPEMENT. PRECAUCIÓNATTENTION PPF127PPM78PPF78 SPL-4 SPL-5 PPF111 PPM112 1 2