Search Results: 18-CH37D1-3A-EN

Showing 1,651 - 1,660 of 7,116 results

Display results per page.
  • Media type icon

    RT-PRC112B-EN_11152025

    16.1Variable_LA 10.7 10.6 10.3 16.6 16.4 16.2 70 Std 10.5 10.2 – 16.1 15.9 –High Eff 11.5 11.2 10.9 17.2 17.0 16.7 Variable_Stage 11.3 11.1 10.7 18.0 17.8 17.5Variable_LA 11.3 11.1 10.7 18.0 17.8 17.5 General Data 18 RT-PRC112B-EN Table 5. EER/IEER ratings (continued) Tons Refrigeration
  • Media type icon

    2TTR2-IN-1B_03012003

    Document Title:Installer’s Guide Condensing Units 2TTR2018-060, 2TTR1018-060 and 2TTR0060
    Publication Type:Installation
    Publication Date:2003-03-01
    2TTR2-IN-1B18-AC51D2-3 © 2003 American Standard Inc. All Rights Reserved 18-AC51D2-3 Installer’s Guide C. ACCUTRON™ FLOW CONTROL VALVEIf the indoor unit System Refrigerant Flow control is anAccutron™ orifice and check valve assembly, an orifice sizechange may be necessary. The outdoor model
  • Media type icon

    BAS-SVX083D-EN_04222021

    Document Title:Enercept FLEX Compact Power and Energy Meter Uni-directional, Bi-directional for BACnet/Modbus
    Publication Type:Installation
    Publication Date:2021-04-22
    systems up to 300 VL-NDielectric Withstand: Per U.L. EN61010, EN 61010-1Conducted/Radiated Emissions: FCC Part 15 Class A, EN61000-6-4/EN61326-1 Class A (Industrial)Conducted/Radiated Immunity: EN61000-6-2, EN61326-1 (Industrial) Agency Approvals: U.S./Canada (cULus): U.L. 61010-1Europe (CE
  • Media type icon

    BAS-PTS003C-EN_12172025

    Document Title:Symbio™ 800 Integration Points List BACnet®/Modbus™ for IntelliPak™
    Publication Type:Points List
    Publication Date:2025-12-17
    occupied standby heating setpoint being used by the controller, considering all possible sources Heat Present and Zone Temperature Control Read °F -40 to 200 Input 30117 BAS-PTS003C-EN Analog Inputs 18 Symbio™ 800 Integration Points List BACnet®/Modbus™IntelliPak™ Date: 12/17/2025 Firmware Release
  • Media type icon

    4619-4480A_03152020

    Document Title:Vertical Unit Ventilators
    Publication Type:Wiring Diagram or Manual
    Publication Date:2020-03-15
    VOLTAJE ALMACENADO. AutoCAD SHX Text DESCONECTE TODA LA ENERGÍA ELÉCTRICA, AutoCAD SHX Text FAILURE TO DO THE ABOVE COULD RESULT IN AutoCAD SHX Text UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT AutoCAD SHX Text N'UTILISER QUE DES CONDUCTEURS EN CUIVRE! AutoCAD SHX Text LES BORNES DE L'UNITÉ NE SONT PAS
  • Media type icon

    2311-4811F_03152020

    Document Title:Vertical Hi Rise - FC/FCV
    Publication Type:Wiring Diagram or Manual
    Publication Date:2020-03-15
    VOLTAJE ALMACENADO. AutoCAD SHX Text DESCONECTE TODA LA ENERGÍA ELÉCTRICA, AutoCAD SHX Text FAILURE TO DO THE ABOVE COULD RESULT IN AutoCAD SHX Text UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT AutoCAD SHX Text N'UTILISER QUE DES CONDUCTEURS EN CUIVRE! AutoCAD SHX Text LES BORNES DE L'UNITÉ NE SONT PAS
  • Media type icon

    KIT03022_08012006

    Document Title:KIT03022 KIT; TAKE-A-PART GASKET & O-RING
    Publication Type:Installation
    Publication Date:2006-08-01
    KIT03022 KIT; TAKE-A-PART GASKET & O-RING COMPONENT Description Item Proc In Date Out Date Qty UOMX23040440010 GASKET; SERVICE VALVE - MODEL E COMPRESSOR, .031 X 5.12 X 4.38, STOCK RAW 10/18/1999 2 EACHX23040438010 GASKET; BITZER, MODEL R COMPRESSOR, .031 X 4.16 X 3.38, CHLOROPRENE (NON-STOCK RAW
  • Media type icon

    BAS-SVP18E-EN_07012022

    Document Title:Tracer® UC600 Programmable Controller Packaged Outdoor Air Unit
    Publication Type:Integration Guide
    Publication Date:2022-07-01
    installed, adjusted or altered equipment by an unqualified person could result in death orserious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. July 2022 BAS-SVP18E-EN Integration GuideTracer®
  • Media type icon

    2311-5360C_09292021

    SUPPLIED CONTROL CIRCUIT WIRING MUST BE COPPER CONDUCTORS ONLY AND HAVE A MINIMUMINSULATION RATING OF 300V. EXCEPT AS NOTED, ALL CUSTOMER WIRING CONNECTIONS ARE MADE TO CIRCUIT BOARDMOUNTED BOX LUGS WITH A WIRE RANGE OF 14 TO 18 AWG. 12 CONTACT RATINGS AND REQUIREMENTS:UNIT PROVIDED DRY CONTACTS FOR THE
  • Media type icon

    BAS-PTS009C-EN_12122025

    Document Title:Symbio™ 800 Integration Points List BACnet® for CenTraVac™ Simplex/Duplex Water-cooled Chillers with Symbio™ Controls
    Publication Type:Points List
    Publication Date:2025-12-12
    Fault Circuit 10 = Normal 1 = In Alarm Unit Mount AFD - AFDN,P (AFD3) MV Remote Mount Comm AFD BI-11019 34020 Diagnostic: AFD Estimated Junction Over Temp Circuit 10 = Normal 1 = In AlarmUnit Mount AFD - AFDN,P (AFD3) BAS-PTS009C-EN Binary Input Diagnostic Simplex 18 Symbio™ 800 Integration Points