Search Results: 18-CH37D1-3A-EN

Showing 1,561 - 1,570 of 7,116 results

Display results per page.
  • Media type icon

    ACC-SVN54U-EN_04202020

    Document Title:High Altitude Conversion Kit
    Publication Type:Installation
    Publication Date:2020-04-20
    HEAT position and adjust the setpoint indicator to its highest setting. The burners should light. 17.If required, adjust the unit manifold pressure to the value listed on the unit nameplate.18.Install the access panel. Table 3. High altitude conversion table Unit Gas Input Rating (MBh) Orifice Size
  • Media type icon

    ACC-SVN98F-EN_04212020

    Document Title:Oversize Motor Kit
    Publication Type:Installation
    Publication Date:2020-04-21
    .17.Replace any wire ties (removed in Step 5) used to secure the motor leads to the cabinet.18.Replace the access panel.19.Close the unit disconnect switch. Table 1. Parts replaced during kit installation Unit MotorMotor SheaveFan Sheave Belt T/YSC072H X X X T/YHC072F X X X X WSC072H X X X X T
  • Media type icon

    22-1633-04_12011996

    Split SystemHeat PumpProduct Data XE 1100TWN018-060C1½ – 5 Ton PUB. NO. 22-1633-04-1296 (EN) GeneralFeatures © American Standard Inc. 1996 2 Pub. No. 22-1633-04-1296 (EN) Split System Heat PumpUnits . . . Designed With YourNeeds In Mind. TWN split systems represent a newapproach to designing
  • Media type icon

    APP-PRC010B-EN_04012025

    APP-PRC010B-EN April 2025 Trane Intelligent VAV SystemsSystem Catalog 2 Trane systems are comprehensive approaches to HVAC system design that support what is best for the building, best for business, and right for the environment. Trane’s Intelligent VAV system is designed to provide superior
  • Media type icon

    COOL-PRC003-EN_02012010

    Document Title:Series Quiet Cooling Tower - Stainless Steel
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2010-02-01
    Series QuietCooling Tower COOL-PRC003-ENFebruary 2010 Stainless Steel COOL-PRC003-EN© 2010 Trane All rights reserved. 3COOL-PRC003-EN Base Performance Construction Mechanical Equipment Fill, Louvers and Drift Eliminators Distribution System and Fan Deck Access and Cold Water Basin Guardrail and
  • Media type icon

    2309-4621R_05042022

    Document Title:RTAC Schematic, 3 Compressor Units, X-Line Starter
    Publication Type:Wiring Diagram or Manual
    Publication Date:2022-05-04
    CE OPTIONS (pg11) CAUTION PRECAUCIÓN ATTENTION AVERTISSEMENT ADVERTENCIAWARNING C TRANE RELEASED 04/May/2022 21:18:34 GMT AutoCAD SHX Text DASHED LINES INDICATE FIELD WIRING BY OTHERS. ALL UNIT POWER WIRING MUST BE COPPER CONDUCTORS ONLY AND HAVE A MINIMUM TEMPERATURE INSULATION RATING OF 90 DEGREE
  • Media type icon

    2309-4622R_05042022

    Document Title:RTAC Schematic, 3 Compressor Units, Y-Delta Starter
    Publication Type:Wiring Diagram or Manual
    Publication Date:2022-05-04
    CE OPTIONS (pg11) CAUTION PRECAUCIÓN ATTENTION AVERTISSEMENT ADVERTENCIAWARNING C TRANE RELEASED 04/May/2022 21:18:34 GMT AutoCAD SHX Text 4 AutoCAD SHX Text 5 AutoCAD SHX Text 6 AutoCAD SHX Text 7 AutoCAD SHX Text 8 AutoCAD SHX Text 9 AutoCAD SHX Text 10 AutoCAD SHX Text TABLE OF CONTENTS AutoCAD
  • Media type icon

    AH-SVX015A-EN_04082023

    Document Title:Installation, Operation, and Maintenance CyberRow DX
    Publication Type:Installation Operation and Maintenance
    Publication Date:2023-05-06
    adequate unit-to-earth ground must be connected to the unit. 18 AH-SVX015A-EN Installation Three-Phase Units Three-phase units are designed to have the L1, L2 and L3 supply wires connected to corresponding L1, L2 and L3 line terminals of the non-fused service switch. The unit will operate correctly
  • Media type icon

    KIT02066_08012006

    Document Title:KIT02066 KIT; GASKET & O-RING, MODEL E HERMETIC, A-L DESIGN SEQUENCE NON-ASBESTOS
    Publication Type:Installation
    Publication Date:2006-08-01
    , MODEL R COMPRESSOR, .031 X 4.16 X 3.38, CHLOROPRENE (NON-STK RAW 10/18/1999 1 EACHPART-IN-47 LITERATURE; LOCATION OF PARTS FOR KIT02066 STK RAW 10/18/1999 1 EACHX23040440010 GASKET; SERVICE VALVE - MODEL E COMPRESSOR, .031 X 5.12 X 4.38, STK RAW 10/18/1999 1 EACHX23130078240 RING; O, NEOPRENE
  • Media type icon

    UV-PRC003V-EN_06092023

    or exceeds the upper limit, the cooling coil control valve is driven open regardless of the need for sensible cooling in the space. The coil over-cools the air, increasing the dehumidification capacity of the system. Figure 9. Part-load dehumidification with modulated chilled water 18 UV-PRC003V-EN