Search Results: TEMP-PRC012A-EN

Showing 1,541 - 1,550 of 7,122 results

Display results per page.
  • Media type icon

    12134905_B_08012024

    Document Title:SCHEMATIC, SHEET 2, PWR, 2-STAGE GH 15T-25T, 208V-230V
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-08-01
    INSERT A FOR THE UNITS WITH ID MOTOR 7.5HP 208-230V/460V/575V MOTORS FROM HTB1 LINE 41, 36 L1L2L3 T1T2T3 + C- 919293 96/U97/V 98/W 68 69 61 155A (G/Y) IGN 24 VAC OUTADDRESS 1 L1 (IN) GROUND COMMONGAS VALVE STAGE 1 FLAME ROD TEMP LIMIT IN ROLLOUT SWITCH IN PRESSURE SWITCH IN L1 (OUT)LOW SPEED (OUT
  • Media type icon

    1213-4845B_09122024

    Document Title:SCHEMATIC; SHEET 2, POWER, DUAL INDOOR FAN, EFLEX, 2-STAGE GAS HEAT, 230V, HIGH SCCR
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-09-12
    FLAME ROD TEMP LIMIT IN ROLLOUT SWITCH IN PRESSURE SWITCH IN L1 (OUT)LOW SPEED (OUT)HIGH SPEED (OUT) MODBUS +MODBUS -COMMON 24 VAC INCOMMON 24 VAC OUT 24 VAC OUT 24 VAC OUT 24 VAC OUT 24 VAC OUT 24 VAC OUT 24 VAC OUT ADDRESS 2 ADDRESS 3 ADDRESS 4 L2 (IN) GAS VALVE STAGE 2 24 VDCGNDHALLPWM 1. SEE
  • Media type icon

    1213-4800A_02142024

    Document Title:SCHEMATIC; SHEET 2, POWER, SINGLE INDOOR FAN, 2-STAGE GAS HEAT, 230V, STD SCCR, MULTI- TAP MOTOR
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-02-14
    PPM511234 PPF151123 2AP(O)3AM(Y) 144A(G/Y) IPSEE POWER EXHAUST SCHEMATIC FOR BALANCE OF CIRCUIT NOTES: FD IGN 24 VAC OUTADDRESS 1 L1 (IN) GROUND COMMONGAS VALVE STAGE 1 FLAME ROD TEMP LIMIT IN ROLLOUT SWITCH IN PRESSURE SWITCH IN L1 (OUT)LOW SPEED (OUT)HIGH SPEED (OUT) MODBUS +MODBUS -COMMON 24 VAC
  • Media type icon

    1213-4941B_08292024

    Document Title:SCHEMATIC; SHEET 2, POWER, SINGLE INDOOR FAN, 2-STAGE GAS HEAT, 460V/575V, STD SCCR
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-08-29
    SCHEMATIC FOR BALANCE OF CIRCUIT 460V INSET A IGN 24 VAC OUTADDRESS 1 L1 (IN) GROUND COMMONGAS VALVE STAGE 1 FLAME ROD TEMP LIMIT IN ROLLOUT SWITCH IN PRESSURE SWITCH IN L1 (OUT)LOW SPEED (OUT)HIGH SPEED (OUT) MODBUS +MODBUS -COMMON 24 VAC INCOMMON 24 VAC OUT 24 VAC OUT 24 VAC OUT 24 VAC OUT 24 VAC OUT 24
  • Media type icon

    PART-SVN160B-EN_05192020

    Document Title:Location of Parts - Motor Change Out Kit, KIT16340, Model Numbers: CVHG / Installation Instructions
    Publication Type:Installation
    Publication Date:2020-05-19
    , adjusted or altered equipment by an unqualified person could result indeath or serious injury. When working on the equipment, observe all precautions inthe literature and on the tags, stickers, and labels that are attached to theequipment. © 2020 Trane Model Number:CVHG May 2020 PART-SVN160B-EN
  • Media type icon

    18-CH12D30-6A-EN_07062020

    Document Title:Installer's Guide - Propane Conversion Kit for 3 Stage Furnaces BAYLPKT220C
    Publication Type:Installation
    Publication Date:2020-07-29
    1000's BTUH QUANTITYOF ORIFICE ORIFICESIZE 60 3 56 80 4 56100 5 56120 6 56 Table 2 Each Kit Contains: Part Number 1Propane LabelConversion LabelConversion Responsibility Label B342003P07 1 Installer's Guide 18-CH12D30-6A-EN 6 Orifice Main Burner #56 - BlackB138253P33 (ORF01428) 2 2" x 3" Coupling
  • Media type icon

    18-CH38D1-7A-EN_07022020

    Document Title:Installer's Guide - Stainless Steel Propane Conversion Kit for 3 Stage Furnaces BAYLPSS220C
    Publication Type:Installation
    Publication Date:2020-07-29
    QUANTITYOF ORIFICE ORIFICESIZE 60 3 56 80 4 56100 5 56120 6 56 Table 2 Each Kit Contains: Part Number 1Propane LabelConversion LabelConversion Responsibility Label B342003P08 1 Installer's Guide 18-CH38D1-7A-EN 6 Orifice Main Burner #56 - BlackB138253P33 (ORF01428) 2 2" x 3" Coupling - PVCA341772P01
  • Media type icon

    18-HD27D1-2A-EN_07062020

    Document Title:Installer’s Guide Outdoor Thermostat Kit
    Publication Type:Installation
    Publication Date:2020-07-30
    -EN GENERAL - SUPPLEMENTARY HEATER STAGINGThe outdoor thermostat (ODT) is designed to turn “ON” the supplementary heater at a pre-selected outdoor temperature. The number and setting of the ODT is dependent on the heat loss of the structure and capacity of the heating system installed. The model ODT
  • Media type icon

    PART-SVN147B-EN_05152020

    Document Title:Location of Parts - Motor Change Out Kit, KIT16326, Model Numbers: CVHE / Installation Instructions
    Publication Type:Installation
    Publication Date:2012-06-15
    , adjusted or altered equipment by an unqualified person could result indeath or serious injury. When working on the equipment, observe all precautions inthe literature and on the tags, stickers, and labels that are attached to theequipment. © 2020 Trane Model Number:CVHE May 2020 PART-SVN147B-EN
  • Media type icon

    18-CH12D28-7B-EN_03022023

    - KIT02851 (White-Rodgers Kit #92-0659) A138928P01 1 Propane Label B342003P021 Conversion Label B342003P021 Conversion Responsibility Label B342003P021 Installer's Guide 18-CH12D16-10A-EN 18-CH12D28-7B-EN CAUTION CAUTION Installer's GuideAt the completion of the conversion, replace the front cover of the