Search Results: TEMP-SVX005C-EN

Showing 1,491 - 1,500 of 7,117 results

Display results per page.
  • Media type icon

    1213-4721_A_02142023

    Document Title:Schematic; Sheet 2, Power, Single Indoor Fan, 2-Stage Gas Heat, 230V, with Supply VFD
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-02-14
    -NEG(R) TXD-POS(BK) BLACKRED BROWN BROWN DRAIN SPL-16 SPL-17 SPL-18GND(BR) DRAIN BLACK BROWNRED 123 FD IP L1 L2 L3 IGN 24 VAC OUTADDRESS 1 L1 (IN) GROUND COMMONGAS VALVE STAGE 1 FLAME ROD TEMP LIMIT IN ROLLOUT SWITCH IN PRESSURE SWITCH IN L1 (OUT)LOW SPEED (OUT)HIGH SPEED (OUT) MODBUS +MODBUS -COMMON
  • Media type icon

    1213-4722_A_02142023

    Document Title:Schematic; Sheet 2, Power, Single Indoor Fan, 2-Stage Gas Heat, 460V, with Supply VFD
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-02-14
    ) SD(BL) RES(R) S1(R)S2(R) SPL-15 S-IN(R) PPF85 123 PPF185 123 BKR MODBUS 3A123 RXD-NEG(R) RXD-POS(BK) TXD-NEG(R) TXD-POS(BK) BLACKRED BROWN BROWN DRAIN SPL-16 SPL-17 SPL-18GND (BR) BLACK BROWNRED 123 FD IP L1 L2 L3 IGN 24 VAC OUTADDRESS 1 L1 (IN) GROUND COMMONGAS VALVE STAGE 1 FLAME ROD TEMP LIMIT IN
  • Media type icon

    1213-4828B_09122024

    Document Title:SCHEMATIC; SHEET 2, POWER, DUAL INDOOR FAN, 2-STAGE GAS HEAT, 230V, STD SCCR
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-09-12
    SPL-1SPL-2SPL-3 SPL-6SPL-7SPL-8 SEE POWER EXHAUST SCHEMATIC NOTES: IGN 24 VAC OUTADDRESS 1 L1 (IN) GROUND COMMONGAS VALVE STAGE 1 FLAME ROD TEMP LIMIT IN ROLLOUT SWITCH IN PRESSURE SWITCH IN L1 (OUT)LOW SPEED (OUT)HIGH SPEED (OUT) MODBUS +MODBUS -COMMON 24 VAC INCOMMON 24 VAC OUT 24 VAC OUT 24 VAC
  • Media type icon

    1213-4986B_10222024

    Document Title:SCHEMATIC; SHEET 2, POWER, SINGLE INDOOR FAN, 2 STAGE GAS HEAT, 460V STD SCCR, FORWARD CURVE FAN
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-10-22
    ) GROUND COMMONGAS VALVE STAGE 1 FLAME ROD TEMP LIMIT IN ROLLOUT SWITCH IN PRESSURE SWITCH IN L1 (OUT)LOW SPEED (OUT)HIGH SPEED (OUT) MODBUS +MODBUS -COMMON 24 VAC INCOMMON 24 VAC OUT 24 VAC OUT 24 VAC OUT 24 VAC OUT 24 VAC OUT 24 VAC OUT 24 VAC OUT ADDRESS 2 ADDRESS 3 ADDRESS 4 L2 (IN) GAS VALVE STAGE 2
  • Media type icon

    18-CH23D2-8A-EN_07162020

    Document Title:Masonry Chimney Vent Kit Model - BAYVENT800B For use with Category I (80%) Upflow Furnaces only!
    Publication Type:Installation
    Publication Date:2020-07-29
    !THIS KIT TO BE APPLIED WITH THE FOLLOWING UPFLOW MODEL FAMILIES ONLY :*UE1, *UD1, M80, *UD-R-V, CUB, and *UD2THIS KIT APPLIES TO ALL INPUTS EXCEPT 40,000 BTU/H* - First letter may be "A" or "T" 18-CH23D2-8A-EN WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING The following warning
  • Media type icon

    18-CD19D7-29-EN_09012016

    Document Title:Installer's Guide - Upflow/Horizontal Downflow/Horizontal, Gas-Fired Furnaces, Fan Assisted Combustion System Models: AUD1, TUD1, ADD1, TDD1
    Publication Type:Installation
    Publication Date:2016-09-01
    18-CD19D7-29-EN Upflow / Horizontal — Downflow / Horizontal, Gas-Fired Furnaces, “Fan Assisted Combustion System” Installer’s Guide Upflow / Horizontal* Downflow / Horizontal* For VENT SIZING INFORMATION see:USA —National Fuel Gas Code ........ ANSI Z223.1/NFPA 54 (latest version) CANADA — Natural
  • Media type icon

    EDU-SLB045-EN_07112025

    Document Title:Energy Strategies for Campus Challenges
    Publication Type:Sales Brochure
    Publication Date:2025-07-11
    your financing and contracting options to determine the best way to achieve your institutional goals. https://www.trane.com/commercial/north-america/us/en/energy-services/financing-implementation.html https://www.trane.com/commercial/north-america/us/en/energy-services/financing-implementation.html
  • Media type icon

    SRV-SLB278-EN_04042024

    Document Title:Rental Services for Data Centers - Temporary Cooling Solutions for Mission-Critical Needs
    Publication Type:Sales Brochure
    Publication Date:2024-04-04
    , including: • Equipment lead times limiting speed to market • Planned maintenance, expansion or emergencies threatening uptime • Additional cooling power required to maintain peak operation and ensure redundancy https://www.trane.com/commercial/north-america/us/en/services/rentals.html https
  • Media type icon

    1213-4842B_09122024

    Document Title:SCHEMATIC; SHEET 2, POWER, DUAL INDOOR FAN, EFLEX, 2-STAGE GAS HEAT, 230V, STD SCCR
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-09-12
    BRR BK BRR DRAIN SPL-27 SPL-3 SPL-2 SPL-1 51A(O) 51A(O) 52A(Y) 52A(Y) BKBK BR BRR R DRAI N 123 MODBUS-2A123 FD IP L1 L2 L3 SEE POWER EXHAUST SCHEMATICFOR BALANCE OF CIRCUIT IGN 24 VAC OUTADDRESS 1 L1 (IN) GROUND COMMONGAS VALVE STAGE 1 FLAME ROD TEMP LIMIT IN ROLLOUT SWITCH IN PRESSURE SWITCH IN L1
  • Media type icon

    PART-SVN86C-EN_08182020

    Document Title:Replacement of VariTrane™ and VariTrac™ Control Modules
    Publication Type:Installation
    Publication Date:2020-08-18
    by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. © 2020 Trane Models: VariTraneVariTracBRD04939 August 2020 PART-SVN86C-EN Installation