  • Media type icon

    RTHD-SVX01N-EN_10312025

    °FFull Load Delta T (across evaporator) = 6°FIce Termination Setpoint (entering water temp.) = 26°FActual Leaving Solution Temperature = 26 - 6 = 20°F Installation Mechanical 40 RTHD-SVX01N-EN Installation ElectricalGeneral RecommendationsAs you review this manual, keep in mind that:• All field
  • Media type icon

    BAS-SVN026H-EN_08062022

    Document Title:Trane® Residential Touch Screen Programmable Zone Sensor for Symbio™ 400/Tracer® UC400 Controls
    Publication Type:Installation
    Publication Date:2022-08-06
    BAS-SVN026-EN.book Trane® Residential Touch Screen Programmable Zone Sensorfor Symbio™ 400/Tracer® UC400 Controls Installation Instructions August 2022 BAS-SVN026H-EN Model Number: X13790992 SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation, starting
  • Media type icon

    FNR-SVX001B-EN_02272026

    Document Title:Installation, Operation, and Maintenance - Upflow/Horizontal and Dedicated Downflow Gas-Fired, Direct/Non-Direct Vent, 2–Stage Condensing Variable Speed Furnaces with Variable Speed Draft Inducer S9V2-VS
    Publication Type:Installation Operation and Maintenance
    Publication Date:2026-02-27
    76,700 2nd Stage Input BTUH 40,000 60,000 80,000 100,000 120,000 2nd Stage Capacity BTUH (ICS)(c) 38,800 58,200 76,900 97,350 116,350 1st Stage Temp. Rise (Min. - Max.) °F 25 - 55 25 - 55 30 - 60 30 - 60 30 - 60 Product Specification FNR-SVX001B-EN 13 Table 4. Models S9V2B040D3VSBB, S9V2B060D3VSBB
  • Media type icon

    ACC-SVN203E-EN_08232024

    August 2024 ACC-SVN203E-EN SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed
  • Media type icon

    RT-PRC091F-EN_09152023

    . RT-PRC091F-EN 19 Table 5. Gross cooling capacities 8.5 tons CFMEntDB (°F) Ambient Temperature (°F) Ambient Temperature (°F) Ambient Temperature (°F) 85 95 105Entering Wet Bulb Temp (°F) Entering Wet Bulb Temp (°F) Entering Wet Bulb Temp (°F) 61 67 73 61 67 73 61 67 73MBh SHC MBh SHC MBh SHC MBh SHC
  • Media type icon

    ODR-SVX024B-EN_04172026

    23.89 10238 0.63 80.00 26.67 9065 0.57 85.00 29.44 8043 0.52 90.00 32.22 7150 0.47 95.00 35.00 6368 0.42 100.00 37.78 5682 0.38 105.00 40.56 5079 0.35 110.00 43.33 4548 0.31 ODR-SVX024B-EN 27 Table 8. Defrost control thermistor (continued) Temp °F Temp °CThermistorResistance(ohms) Volts DC 115.00 46.11
  • Media type icon

    PKGP-PRC013AA-EN_12202022

    heat applications minimum airflow is set to 320 cfm/ton, unless specified otherwise, values found in electric heat temp rise table. 4. Data includes pressure drop due to wet coil and filters. 58 PKGP-PRC013AA-EN Evaporator Fan Performance Table 35. Multispeed direct drive evaporator fan performance
  • Media type icon

    HDWA-SVX002E-EN_05262025

    -EN 13. 4BP2, Condenser Refrigerant Pressure Transducer Ckt 114. 4BT7, Compressor Discharge Temperature Sensor Ckt 115. 4BT8, Economizer Temperature Sensor Ckt 116. 4M2, Evaporator EXV 1 Ckt 117. 4M4, Economizer Valve Ckt 118. 4M6, Drive Cooling Valve Ckt 119. 4BT4, Drive Cooling Supply Temp Sensor
  • Media type icon

    ACC-SVN209E-EN_08232024

    Document Title:Reference Enthalpy — Foundation™ Packaged Rooftop Units with Low Leak Economizer 3 to 5 Tons
    Publication Type:Installation
    Publication Date:2024-08-23
    Outside AirSensor Installation Instructions Reference EnthalpyFoundation™ Packaged Rooftop Units withLow Leak Economizer3 to 5 Tons Model Number: Used With:BAYENTH322* E/GB*036-060 E/GD*036-060 August 2024 ACC-SVN209E-EN 9 1110 12 13 14 8 ©2024 Trane and American Standard have a policy of continuous
  • Media type icon

    BAS-PTS037A-EN_07312025

    Document Title:Symbio™ 500 Integration Point List BACnet® Modular Self-Contaned (SCWM*)
    Publication Type:Points List
    Publication Date:2025-07-31
    Document: BAS-SVP087*-EN Object IdentifierObject Name Description Configuration Dependency Read/ WriteUnits Low Limit High Limit AI-1 Space Temperature LocalIndicates the space temperature value from a sensor wired to the controller Unit Controls = Space Control or VAV with Space temp resetRead °F -58