Search Results: 18-CH37D1-3A-EN

Showing 1,271 - 1,280 of 7,121 results

Display results per page.
  • Media type icon

    1213-5021B_09112024

    Document Title:SCHEMATIC; SHEET 4, CONTROLS, ADAPTER BOARD UNIT CONTROLS, SINGLE COMPRESSOR, DUAL FAN, EFLEX
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-09-11
    OPTIONS THAT REQUIRECUSTOMER PROVIDED WIRING OPTIONAL HOTGAS REHEAT OPTIONAL HOTGAS REHEAT CONNECT CUSTOMER SUPPLIED DEVICE TO VHR-TB FOR VENTILATION HEATOPERATION. VHR RELAY IS ACTIVE WHEN UNIT IS IN HEAT MODE.ELECTRICAL RATING FOR VHR CONTACTS: 3A @ 277VAC 575VONLY OPTIONALGAS HEAT P20 1 2 3 4 5 6 7 8
  • Media type icon

    22-1939-1C-EN_06122020

    Product DataSplit System (R-410A)23 Series, Inverter System 9,000 to 36,000 BTU/Hr 22-1939-1C-EN Single Split Indoor Unit Outdoor UnitHeat Pump 4MXW23-A 4TXK23-A 2 Quiet DesignSpecially designed air vent efficiently reduces operation noise, as low as 29 dB. Function/Fan SpeedHigh speed operation
  • Media type icon

    23116081_A_08232023

    RANGE OF 14TO 18 AWG. DO NOT RUN LOW VOLTAGE CONTROL WIRING (30 VOLTS OR LESS) IN CONDUIT WITH 110 VOLT OR HIGHER WIRING. DO NOT EXCEEDTHE FOLLOWING MAXIMUM RUN LENGTHS FOR A GIVEN SIZE: 14 AWG, 5000 FT; 16 AWG, 2000 FT; 18 AWG, 1000 FT. THE CONTACTS FOR THESE FEATURES ARE JUMPERED AT THE FACTORY BY
  • Media type icon

    PART-SVN72C-EN_12182015

    Document Title:Location of Parts - Motor Change Out Kit, KIT16386, Model Number: CVHF / Installation Instructions
    Publication Type:Installation
    Publication Date:2015-12-18
    waste. © 2015Trane All rights reservedPART-SVN72C-EN 18 Dec 2015Supersedes PART-SVN72B-EN (08 Jun2012) 6 Table 2. Part numbers referenced in Figure 4 Part # Qty. Location and Use Ref # RNG02128 1 O-ring; suction elbow to evap 32 RNG02106 1 O-ring; volute to cond 33 GKT02694 1 Sealant; comp to suct
  • Media type icon

    ACC-SVN270B-EN_08232024

    Document Title:Low Ambient Control — Foundation™ Packaged Rooftop Units 3 to 5 Tons
    Publication Type:Installation
    Publication Date:2024-08-23
    August 2024 ACC-SVN270B-EN SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed
  • Media type icon

    BAS-PTS014A-EN_11152024

    Document Title:Symbio™ 800 Integration Points List LonTalk® for Sintesis™ Air-Cooled Chiller Model RTAF
    Publication Type:Points List
    Publication Date:2022-04-30
    Symbio™ 800 Integration Points ListLonTalk®Sintesis™ Model RTAF Date:11/15/2024Reference Document: BAS-SVP084*-EN Profile Definition and Network Variables The following tables are sorted as follows: • Tables are listed by unit/profile type and sorted by network variable number.• Tables are sorted
  • Media type icon

    BAS-PTS028A-EN_12062024

    Symbio™ 800 Integration Points ListBACnet®HDWA (UC800) Date: 12/6/2024Reference Document: BAS-SVP083*-EN Object Naming ConventionsThe communicated points for the Symbio™ controllers are generally named according to their function. While many of the points are read-only, others include both read and
  • Media type icon

    BAS-PTS026A-EN_12062024

    Document Title:Symbio™ 800 Integration Points List BACnet®/Modbus™ for ACSA (UC800)
    Publication Type:Points List
    Publication Date:2024-12-06
    Symbio™ 800 Integration Points ListBACnet®ACSA (UC800) Date: 12/6/2024Reference Document: BAS-SVP083*-EN Object Naming ConventionsThe communicated points for the Symbio™ controllers are generally named according to their function. While many of the points are read-only, others include both read and
  • Media type icon

    18-HE140D1-1A-EN_11272024

    Document Title:Installer's Guide -Horizontal Economizer and Rain Hood: BAYECON207A, BAYECON208A and BAYRLAY006B
    Publication Type:Installation
    Publication Date:2024-11-29
    supply through wire leads. The economizer is fully accessible through an access panel. Use care when inserting the economizer in the return air compartment, to prevent damaging the foil faced insulation. 18-HE140D1-1A-EN Installer’s Guide ALL phases of this installation must comply with NATIONAL
  • Media type icon

    AC-SVX003E-EN_02262026

    Modules 8 8 10 8 10 10 12 10 12 10 12 12 14 14 16 16 18 Quantity of Fans 8 8 10 8 10 10 12 10 12 10 12 12 14 14 16 16 18 Fan Diameterin 37.5 mm 953 12 AC-SVX003E-EN Table 1. General data - 150 to 330 ton units (continued) Unit Size (tons) 150 165 180 200 225 250 275 300 330 Coil Lengthin 78 mm 1987 Coil