Search Results: 18-HE82D1-2B-EN

Showing 1,241 - 1,250 of 7,186 results

Display results per page.
  • Media type icon

    SO-SVN024A-EN_08312023

    Document Title:Variable Frequency Drive Conversion TR1 to TR200 IntelliPak™ I and II and Voyager™ 3 only
    Publication Type:Installation
    Publication Date:2023-08-31
    components in order on each stud: Large VFD Fuse bracket assembly installed Figure 6. TR200 Schematic SO-SVN024A-EN 11 Installation of TR200 VFD and Components 1 Fuse standoff (HEX0.63 FF0.31-180.50 AL) 2 Fuse 3 Flat washer (0.31x.688x.070 ST) 4 Lock washer (SPL .31x.580x.082 ST) 5 Hex nut (0.31-18 ST
  • Media type icon

    2309-4870H_02242022

    LOCAL APPLICABLE CODES. ALL CUSTOMER CONTROL CIRCUIT WIRING MUST BE COPPER CONDUCTORS ONLY AND HAVE A MINIMUM INSULATION RATING OF 300 VOLTS.EXCEPT AS NOTED ALL CUSTOMER WIRING CONNECTIONS ARE MADE TO CIRCUIT BOARD MOUNTED BOX LUGS WITH A WIRE RANGE OF 14TO 18 AWG. DO NOT RUN LOW VOLTAGE CONTROL
  • Media type icon

    DLR-SVX026A-EN_12132025

    Document Title:19-23 Seer 2 Single Zone Ductless Mini-Split Heat Pump
    Publication Type:Installation Operation and Maintenance
    Publication Date:2025-12-13
    18 DLR-SVX026A-EN Refrigerant SensorWARNING Leak Detection System Installed!Failure to follow instructions below could result indeath or serious injury or equipment damage.The unit is equipped with electrically powered safetymeasures and must be powered at all times afterinstallation, except during
  • Media type icon

    ACC-SVN240C-EN_10042024

    Document Title:Discharge Air Sensing (DAS) Kit Precedent™ Packaged Rooftop Units
    Publication Type:Installation
    Publication Date:2024-10-04
    Installation Figure 13. FIADAST003 and FIADAST005 - Installed Figure 14. FIADAST004 and FIADAST006 - installed 18 ACC-SVN240C-EN Installation • Figure above shows FIADAST009 supply side tubing with a high-heat exchanger. • Factory downflow configuration is shown. For field-installed downflow applications
  • Media type icon

    ODR-SVX008C-EN_04172026

    require wirenuts for connections.2) Cap all unused wires.3) In AC systems, for multiple stages of electric heat, jumper W1and W2 together if comfort control has only one stage of heat. W3Brown HEATING2nd STAGE HEATING3rd STAGE Electrical 18 ODR-SVX008C-EN Figure 25. AC or heat pump, typical (with furnace
  • Media type icon

    18-CD21D1-15-EN_04012015

    Document Title:Installer's Guide - High Efficiency Single Stage Upflow / Horizontal and Downflow / Horizontal Gas-Fired Furnaces, "Fan Assisted Combustion System" Models: AUD1-H, TUD1-H, ADD1-H, TDD1-H
    Publication Type:Installation
    Publication Date:2015-04-01
  • Media type icon

    18-DE02D1-1 _01012014

    Document Title:Ordering Information Variable and Non-Varialbe Speed High Efficiency Oil Furnaces
    Publication Type:Installation
    Publication Date:2014-01-01
  • Media type icon

    18-EB26D1-16A-EN_07082020

    Document Title:Installer's Guide Single Packaged, Cooling w/ Electric Heat, 14 SEER, Convertible, 2 - 5 Ton, R-410A
    Publication Type:Installation
    Publication Date:2020-07-08
    interpretation of this information, nor can it assume any liability in connection with its use. ss WARNING 18-EB26D1-16A-EN WARNING!This product can expose you to chemicals including lead, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more
  • Media type icon

    18-HE110D1-1A-EN_05012018

    Document Title:Envirowise Dehumidifier & Ventilation System Controller D30, D30R
    Publication Type:Installation
    Publication Date:2018-05-01
    INSTALLER’S & OWNER’S MANUALHVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER Dehumidifi er & Ventilation System Controller D30D30R Part No. E4037893 18-HE110D1-1A-EN TS-994 Rev. 2 5/24/18 Table of Contents1. Specifi cations ............................................................ 22
  • Media type icon

    18-HE103D1-1A-EN_07012018

    Document Title:Envirowise 98H Whole House Ventilating Dehumidifier EDHUM098
    Publication Type:Installation
    Publication Date:2018-07-01
    right to change design and specifi cations without notice. We are committed to using environmentally conscious print practices. 18-HE103D1-1A-EN (JUL 2018)Supersedes (NEW) ©2018 Ingersoll Rand | all rights reserved