    ODR-SVX031A-EN_03202026

    Document Title:Heat Pumps
    Publication Type:Installation Operation and Maintenance
    Publication Date:2026-03-20
    outside of the unit with apermanent marker. System Charge Adjustment 26 ODR-SVX031A-EN a. Charge added at Factory = ___________ lb/ozb. Charge added at install = ___________ lb/ozc. Total System Charge (a + b) = ___________ lb/oz Subcooling Charging Below 55ºF Outdoor Temp. (In HeatingOnly)The
  • Media type icon

    UV-PRC003V-EN_06092023

    0.9580 0.97 0.89 Table 15. Airflow through coil JUnit Model 0750Rated cfm 748 38 UV-PRC003V-EN Performance Data Table 16. VUV 075, hydronic heating coils A (1-row / 12 fpi), B (2-row / 12 fpi), C (2-row / 16 fpi) Coil Entering Air Temp, Dry Bulb (°F)Entering Water Temp (°F) Flow Rate (gpm)2 4 6 Total
  • Media type icon

    BAS-PRD034C-EN_10272023

    Document Title:Enercept FLEX© Compact Power and Energy Meter Uni-directional, Bi-directional for BACnet® and Modbus®
    Publication Type:Product Data
    Publication Date:2023-10-27
    October 2023 BAS-PRD034C-EN SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed
  • Media type icon

    ACC-SVN248C-EN_10072024

    Document Title:CO2 Sensing Kit Precedent™ Packaged Units with Symbio™ 700 3 to 12.5 Tons
    Publication Type:Installation
    Publication Date:2024-10-07
    ACC-SVN248-EN SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipmentcan be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered
  • Media type icon

    FNR-SVX003A-EN_10312025

    PROBE 1 2 RAF-2 BLOWERMOTOR RX N GND J1 J2 TX V L1 C 2 1 THERMISTOR S8V2-C SEE NOTE #6 Wiring Diagrams FNR-SVX003A-EN 19 Airflow TablesTable 7. Heating airflow performance – model S8V2A040M3P S8V2A040M3P Furnace Heating Airflow (CFM), Temp. Rise (°F), and Power (Watts) vs. External Static Pressure with
  • Media type icon

    PKGP-SVX19A-EN_05052023

    unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. Mayo 2023 PKGP-SVX19A-EN Confidential and proprietary Trane information Installation
  • Media type icon

    ODR-SVX010B-EN_04172026

    Document Title:Heat Pumps
    Publication Type:Installation Operation and Maintenance
    Publication Date:2026-04-17
    or altered equipment by an unqualified person could result in death orserious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. April 2026 ODR-SVX010B-EN Heat
  • Media type icon

    DHWHP-SVX001A-EN_07132025

    Document Title:T270WM Modular Domestic Hot Water Heat Pump
    Publication Type:Installation Operation and Maintenance
    Publication Date:2025-07-13
    outlet temps are set correctly. Single-pass: Internal control valve is working properly. Outlet temp is allowed by current ambient temps. Troubleshooting DHWHP-SVX001A-EN 37 Table 10. Alerts and faults Alert/Fault Trigger Check High pressure Refrigerant pressure is too high All Outlet Flow checks are
  • Media type icon

    DHWHP-SVX002A-EN_07132025

    Document Title:T125W Modular Domestic Hot Water Heat Pump
    Publication Type:Installation Operation and Maintenance
    Publication Date:2025-07-13
    LWTconditions,and does not generate heat demands internally. Therefore,there are no water temperature targets to set on the unit.The heat pump will simply run in response to demands untildemand is satisfied or high temp safeties are reached. Configuration 32 DHWHP-SVX002A-EN Pre-Startup ChecklistThe following
  • Media type icon

    DHWHP-SVX003A-EN_07132025

    Document Title:T185W Modular Domestic Hot Water Heat Pump
    Publication Type:Installation Operation and Maintenance
    Publication Date:2025-07-13
    are used, a single temp sensor can pick any tank to trigger heating operation. However, the maincontrol accessory can be used to add averaging of multiple tank sensors, which is more ideal for multiple, multi-passtank systems. Water Piping — DHW Loop DHWHP-SVX003A-EN 21 Water Piping — Source