Search Results: 18-HD83D1-5B-EN

Showing 1,191 - 1,200 of 7,116 results

Display results per page.
  • Media type icon

    RLC-PRC033-EN_09012009

    Document Title:Made in China 60 Hz - Product Catalog - Series R Helical Rotary Water-Cooled Liquid Chillers - Model RTWD 75–250 Tons
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2009-09-01
    Data - 60 Hz - standard efficiency - I-P units Evaporator Leaving Water Temp (°F) Condenser Entering Water Temperature (°F) 75 85 95 Unit kW kW kW Size Tons Input EER kW/ton Tons Input EER kW/ton Tons Input EER kW/ton 18 RLC-PRC033-EN Performance Data Table 6. Performance Data - 60 Hz - high
  • Media type icon

    FNR-PSD013B-EN_03272026

    isrecommended that the fan only be used in the AUTO mode. Airflow TablesPreliminary 18 FNR-PSD013B-EN Table 14. *UHMB080CCV3VA^ cooling airflow Outdoor Tonnage(tons) Airflow Setting(CFM/ton) EXTERNAL STATIC PRESSURE (IN. W. C.) VS. CFM/WATTS 0.1 0.3 0.5 0.7 0.9 2.0 290 504 / 34 565 / 70 586 / 104 521
  • Media type icon

    ARTC-SLB010-EN_02132026

    Document Title:Thermafit™ Modular Air-to-Water Heat Pump Chiller Model AXM
    Publication Type:Sales Brochure
    Publication Date:2026-02-13
    requirements, streamlining installation and commissioning ECM FANS Improve efficiency and acoustics at part load conditions SLOPED DRAIN PAN Improved condensate management during defrost cycles 6 6 Measurements © 2026 Trane. All Rights Reserved | ARTC-SLB010-EN | 02/13/2026 All trademarks referenced in
  • Media type icon

    12134662_B_02202023

    Document Title:SCHEMATIC; ELECTRIC HEAT 140KW
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-02-20
    THEWRITTEN CONSENT OF TRANE. DESIGNER:ENGINEER:TRANE © DATE:REPLACES: SIMILAR TO: REVISION DATE:REVISED BY:APPROVED BY:CAD SYSTEM USED: MASTER NUMBER: DRAWING NUMBER: SHEET: REV R JOHNSONR. ROBINSON 13-SEPT-2022 18-OCT-2022R JOHNSON R. ROBINSONCREO SCHEMATICS 12134662 BOF13 17 IPAK 2SCHEMATIC
  • Media type icon

    1213-4336G_11212023

    Document Title:SCHEMATIC; SHEET 1, POWER, DUAL COMPRESSOR, DUAL CONDENSER FAN, HIGH SCCR
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-11-21
    . CAUTION¡UTILICE ÚNICAMENTE CONDUCTORES DE COBRE! LAS TERMINALES DE LA UNIDAD NO ESTÁN DISEÑADASPARA ACEPTAR OTROS TIPOS DE CONDUCTORES. SI NO LO HACE, PUEDE OCASIONAR DAÑO AL EQUIPO. N'UTILISER QUE DES CONDUCTEURS EN CUIVRE! LES BORNES DE L'UNITÉ NE SONT PAS CONÇUESPOUR RECEVOIR D'AUTRES TYPES DE
  • Media type icon

    PKG-SVX030B-EN_11152025

    14.5 General Data PKG-SVX030B-EN 13 Table 2. SCWM water-cooled self-contained, 60 to 110 tons (continued) Tonnage 60 Ton 60 TonNY 60 TonSplit 70 Ton 80 Ton 80 Ton NY 90 Ton 100 Ton110 Ton Filter Data, Water-Cooled Units Number - Size (in.) 12 - 24"x 20" 12 - 24"x24" 12 - 24"x 20" 18 - 24" x 20
  • Media type icon

    RT-PRC078H-EN_12032022

    ) = 0.50 wg. With 2000 cfm and 0.50 wg. Table 18, p. 33 shows 0.83 bhp for this unit. Note below the table is theformula to calculate fan motor heat. 14 RT-PRC078H-EN 2.8328 x Fan bhp + 0.4714. 2.8328 x 0.83 + 0.4714 = 2.82 MBh Now subtract the fan motor heat from the gross cooling capacity of the unit:Net
  • Media type icon

    ACC-SVN230C-EN_09152024

    Document Title:High Altitude Conversion Kit Precedent™ Packaged Rooftop Units 3 to 25 Tons Two-Stage Gas
    Publication Type:Installation
    Publication Date:2024-09-15
    the setpoint indicator to its highest setting. The burners should light. 17. If required, adjust the unit manifold pressure to the value listed on the unit nameplate. 18. Install the access panel. ACC-SVN230C-EN 7 Installation – FIAHALT003* Carefully review installation instructions to convert gas
  • Media type icon

    AHR-SVX003C-EN_03212026

    energized. Installation Instructions 18 AHR-SVX003C-EN If the indoor temperature continues to fall, the R to Wcircuit is completed energizing the electric heatcontactor(s).Heating (electric heat only)Note: The thermostat must be setup to bring the blower on when the electric heat is energized.When the
  • Media type icon

    BAS-PTS007B-EN_04302025

    Document Title:Symbio™ 800 Integration Points List for BACnet®/Modbus™ Agility™ Water-Cooled Chillers with Symbio™ Controls
    Publication Type:Points List
    Publication Date:2025-04-30
    Values 18 Symbio™ 800 Integration Points List BACnet®/Modbus™Agility™ Water-Cooled Chillers Date:4/30/2025 Reference Document: BAS-SVP083*-EN BACnet Object Identifier Modbus RegisterObject Name Object States Configuration Dependency MI-10100 32011 Operating Mode 1 = Cool 2 = Heat 3 = Ice Making 4