Search Results: 18-HE125D1-1C-EN

Showing 1,171 - 1,180 of 7,119 results

Display results per page.
  • Media type icon

    FNR-PSD003A-EN_07012025

    Document Title:Upflow/Downflow/Horizontal Gas-Fired, 1–Stage and 2–Stage Induced Draft Furnaces with High Efficiency Motor
    Publication Type:Product and Submittal Data
    Publication Date:2025-07-01
    . H1. E2.1 E2.2 E2.3 E3.1 E3.2 E04 E6.1 E01 E6.2 E6.3 E7.1 E08 E12 E11 SEE NOTE 1 SEE NOTE 1 S8X1 Wiring Diagrams FNR-PSD003A-EN 17 Figure 4. S8X1 — ladder diagram S8X1 Wiring Diagrams 18 FNR-PSD003A-EN Figure 5. S8X2 — wiring diagram Wiring Diagrams FNR-PSD003A-EN 19 Figure 6. S8X2 — ladder diagram
  • Media type icon

    ODR-SVX009B-EN_04172026

    Document Title:Heat Pumps
    Publication Type:Installation Operation and Maintenance
    Publication Date:2026-04-17
    , for multiple stages of electric heat, jumper W1and W2 together if comfort control has only one stage of heat. W3Brown HEATING2nd STAGE HEATING3rd STAGE Electrical 18 ODR-SVX009B-EN Figure 26. AC or heat pump, typical (with furnace) Furnace Evaporator Coil MCB FurnaceOutdoor Unit R G B W1 W2 R B O Y/Y1
  • Media type icon

    BAS-PTS037A-EN_07312025

    Document Title:Symbio™ 500 Integration Point List BACnet® Modular Self-Contaned (SCWM*)
    Publication Type:Points List
    Publication Date:2025-07-31
    Regulating Valves Read/ WriteOff false = Off true = Active Purge BAS-PTS037A-EN Binary Values 18 Symbio™ 500 Integration Point List BACnet®Modular Self-Contaned (SCWM*) Date:07/31/2025 Firmware Release:V2.2 Reference Document: BAS-SVP087*-EN Object IdentifierObject Name Description Configuration
  • Media type icon

    FIN-PRC011B-EN_04242020

    Document Title:Electric Wall FIN Architectural Convectors
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2020-04-24
    /DBT is not suitable or ETL listed for residential applications. 18 FIN-PRC011B-EN Mechanical Specifications and Dimensions Dimensions Figure 5. DBF-DBT architectural pedestal heaters 2.0”(50.8 mm) 2.0”(50.8 mm) (609.6 mm Thru 3048 mm)2 FT THRU 10FT LENGTHS (609.6 mm Thru 3048 mm)2 FT THRU 10FT LENGTHS
  • Media type icon

    TEMP-PRC001C-EN_12132024

    Heat Capacity. TEMP-PRC001C-EN 17 Voyager™ with Electric Heat Unit Drawings – CSDX0025F4DE-EB Table 17. Electric heating performance – CSDX0025F4DE-EB CFM Temp Rise (°F) 7000 32.4 8000 28.3 9000 25.2 10000 22.7 11000 20.6 Table 18. Sound data – CSDX0025F4DE-EB Sound Path (Hz) 63 125 250 500 1K 2K 4K
  • Media type icon

    COIL-SVX01G-EN_12012025

    -1.4mRelease Height-1.8mRelease Height-2.2m A2L Information and Installation Requirements COIL-SVX01G-EN 17 Figure 3. R-32 charge vs min room area (IP) 0 5 10 15 20 25 30 35 40 45 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 Min imum Roo m A rea (ft2 ) Charge (lb) R-32 Charge
  • Media type icon

    CAUK-SVX001B-EN_05082025

    ACCESS 1 1/4" x 4 1/2"SLOT FOR 115V ACCESS DETAIL ACONTROL BOX BOTTOM FRONT (SEE NOTE3 FOR ALL MIN.CLEARANCE) VENTILATION 4 2 4 2 4 4 Dimensions and Weights 18 CAUK-SVX001B-EN Figure 7. Air-cooled condenser connections — 40 ton 5 7/16" 49 13/32" 27 13/32"10 15/32" 41 7/8" 2 7/8"27 11/32" 5 3/4
  • Media type icon

    ODR-SVX024B-EN_04172026

    Document Title:Heat Pump
    Publication Type:Installation Operation and Maintenance
    Publication Date:2026-04-17
    , remove factory Y1 - O jumper at furnace (if equipped). 3. For +TSTAT, connect W2 to W2 and Y2 to Y2. 4. For Link enabled systems, omit all 24V wiring and use "CAN" connection only.5. X2 is necessary if not using select Trane or American Standard thermostats. Electrical 18 ODR-SVX024B-EN Figure 25
  • Media type icon

    CDHH-SVX003F-EN_04112026

    366 930 852 2164 38 97 118 300 440M/44HM 120 305 318 808 756 1920 38 97 118 300 18 CDHH-SVX003F-EN Table 5. Clearance requirements (continued) Shell ComboA B C D E in. cm in. cm in. cm in. cm in. cm 440X/44HX 120 305 366 930 852 2164 38 97 118 300 Note: All dimensions are approximate; refer to the
  • Media type icon

    18-BC94D1-1 _10012013

    Document Title:Installer's Guide for special Personality Module (PM) for use in extreme weather conditions - CONTACT YOUR LOCAL FSR FOR ORDERING INFORMATION
    Publication Type:Installation
    Publication Date:2013-10-01