Search Results: 18-CH83D1-1B-EN

Showing 1,051 - 1,060 of 7,142 results

Display results per page.
  • Media type icon

    DLR-SVN001A-EN_05012025

    Document Title:Variable Speed Side Discharge HP 2 Ton R454B
    Publication Type:Installation
    Publication Date:2025-05-01
    ] Max. 500 [20] 300 [12] 300 [12] 300 [12] 500 [20] Max. 300 [12] 1000 [40] 1000 [40] 1000 [40] 1000 [40] 1000 [40] 1000 [40] mm [inch] 1000 [40] 150 [6] Fig. 2-6 Fig. 2-8 Fig. 2-9 Fig. 2-10 Fig. 2-12 Fig. 2-14 Fig. 2-15 Fig. 2-16 Fig. 2-17 Fig. 2-18 Fig. 2-7 Fig. 2-11 Fig. 2-13 100 [4] 300 [12] en
  • Media type icon

    MS-SVN055B-EN_09132018

    Document Title:Split System (R-410A) Inverter Units 18 36,000 BTU/Hr - 60 Hz / Installer’s Manual
    Publication Type:Installation
    Publication Date:2018-09-13
    connection piping and refrigerant capacity been recorded? The refrigerant capacity is not accurate 16 MS-SVN055B-EN Connecting Pipe- 60 Hz Connecting Pipe- 60 Hz 18 SEER60Hz (Cooling only and Heat Pump) 4MYW8536A1 4TYK8536A1 4MXW8536A14TXK8536A1 Refrigerant charge (kg) R410A/2.60Length (m) 7.6 Additional
  • Media type icon

    PKGR-SVX003C-EN_10062025

    Document Title:Single Packaged Heat Pump, Choice, Convertible, 2 - 5 Ton, R-454B, 5WCC4
    Publication Type:Installation
    Publication Date:2025-10-06
    5WCC4042 1000.13[39.38] 457.20 [18]75.41[2.97] 75.41[2.97] 381.00[15] 244.09[9.61] 318.75[12.55] 381.00[15] 79.50[3.13] 449.02[17.68] 176.07[6.93] 322.84[12.71] 372.82[14.68] 1402.34[55.21] 5WCC4048 5WCC40601050.93[41.38] Dimensional Data 16 PKGR-SVX003C-EN Table 5. Weights and center of gravity
  • Media type icon

    ACC-SVN208G-EN_08232024

    Document Title:Horizontal and Downflow Standard Economizer — Foundation™ Packaged Rooftop Units 3 to 5 Tons
    Publication Type:Installation
    Publication Date:2024-08-23
    18. Install block-off angle Figure 19. Apply gasket Economizer Filter Rack Gasket Figure 20. Mist eliminator servicing Mist EliminatorMist Eliminator Bracket ACC-SVN208G-EN 11 Installation Minimum Position SettingTo adjust the minimum position setting and check out the economizer, the power must be
  • Media type icon

    BAS-SVX20K-EN_04152020

    Document Title:Tracer® UC400 Programmable Controller
    Publication Type:Installation Operation and Maintenance
    Publication Date:2020-04-15
    . • Analog outputs: check that no A/C voltage is present and that the load has no 24 Vac across itor 120 Vac. WWiirriinngg 18 BAS-SVX20K-EN Point Check DiagramThis section shows diagrams and describes methods to check device input/output points beforethe connection to the UC400 controller has been made
  • Media type icon

    RT-SVX23R-EN_09222022

    MM198 MM 12”12” 304 MM304 MM 16 3/4”16 3/4”425 MM425 MM 6 7/8”6 7/8”175 MM175 MM 18 RT-SVX23R-EN Dimensions and Weights Figure 20. Heat pumps - 5 to 10 tons standard efficiency, 4 to 8.5 tons high efficiency - swing diameter for hinged door(s) option 21 3/8”543 MM 17”432 MM 34 5/8”879 MM Applicable
  • Media type icon

    18-HE85D1-1D-EN_09092022

    Document Title:Installer's Guide - Down Discharge Economizer and Rain Hood Models: BAYECON103AA/AB/AC, BAYECON104AA/AB/AC and BAYRLAY006A
    Publication Type:Installation
    Publication Date:2022-09-09
    the unit low voltage supply through wire leads. The economizer is fully accessible through the Coil access panel. 18-HE85D1-1D-EN Installer’s Guide ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING Important
  • Media type icon

    PART-SVN155B-EN_05182020

    Document Title:Location of Parts - Motor Change Out Kit, KIT16334, Model Numbers: CVHG / Installation Instructions
    Publication Type:Installation
    Publication Date:2020-05-18
    residentialapplications. For more information, please visit trane.com or tranetechnologies.com. PART-SVN155B-EN 18 May 2020 Supersedes PART-SVN155A-EN (Jun 2012) 6Table 2. 565 Compressor 050 Shells Part numbers referenced in Figure 4 Figure 4. Refer to Table 2 for part location and use Part # Qty. Location and Use Ref
  • Media type icon

    RT-PRC130B-EN_05162026

    Document Title:Foundation™ Packaged Rooftop Units Cooling and Gas/Electric 7.5 to 12.5 Tons
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2026-05-16
    or Max Circuit Breaker Min Circuit Ampacity Max Fuse Size or Max Circuit Breaker 7.5 E/GDK090* 208-230 35 45 39 50 8.5 E/GDK102* 208-230 38 45 45 50 10 E/GDK120* 208-230 50 60 52 60 12.5 E/GDK150* 208-230 62 80 64 80 7.5 E/GDK090* 460 18 20 23 25 8.5 E/GDK102* 460 20 25 27 30 10 E/GDK120* 460 28 30
  • Media type icon

    18-CH87D1-1D_10282022

    Document Title:Installer's Guide Steam Humidifier EHUMD800ASM00BA / EHUMD800BSMLCBA
    Publication Type:Installation
    Publication Date:2022-10-28
    (distance minimale du tube de dispersion en amont de toute obstruction ou courbe dans le conduit) Capacité de l’humidificateur (litres/jour) Vélocité du débit d’air* 21 °C et valeur de réglage de 30 % d’HR 21 °C et valeur de réglage de 45 % d’HR 18 °C et valeur de réglage de 45 % d’HR Valeur de