Search Results: YZC*

Showing 1 - 10 of 40 results

Display results per page.
  • Media type icon

    RT-SVX45F-EN_04022020

    Document Title:Packaged Rooftop Air Conditioners Precedent™ with eFlex™ Technology, Electric/Electric 3 to 10 Tons - 60 Hz
    Publication Type:Installation Operation and Maintenance
    Publication Date:2020-04-02
    -EN 15 Dimensions and Weights Table 2. Factory installed options (fiops)/accessory net weights (lbs)(a) (b), Accessory T/YZC036E T/YZC048F-060E T/YZC072F T/YZC090-102F T/YZC120F Net Weight Net Weight Net Weight Net Weight Net Weight 3 Tons 4 to 5 Tons 6 Tons 7.5 to 8.5 Tons 10 Tons Barometric Relief
  • Media type icon

    ACC-SVN05Q-EN_04242020

    Document Title:ReliaTel™ Options Module Used with 3 to 10 Ton Packaged Units with ReliaTel™ Controls
    Publication Type:Installation
    Publication Date:2020-04-24
    mounting bracket with 1 screw. Refer to Figure 1. 3. On all units except Y/TSC036-060G, D/W*C036-060H, Y/TSC120F, Y/THC092-102E, T/YHC120F, T/YZC072-120, Y/THC074-120F and WSC120E, install the RTOM and bracket assembly to the unit. Refer to Figure 1. 4. On Y/TSC120F, Y/THC092-102E, T/YHC120F, T/YZC072
  • Media type icon

    ACC-SVN11N-EN_06032020

    Document Title:Ventilation Override Kit Used with 3 to 10 Ton Packaged Units with ReliaTel™ Controls
    Publication Type:Installation
    Publication Date:2020-06-03
    /YZC048-060 — 2 1/8” 2” Figure 3. Wiring Install - All units except T/YHC092-120E, T/YHC120F, T/YZC120 & D/WHC120H T/YSC036-060GWSC036-048H, D/WHC036HT/YHC036-037ET/YZC036, 048F, 060E Route wiring between coil blockoffand roof for the following units: T/YSC072-120 WSC072E-120E/H, WSC060H, D/WHC048-060H,T
  • Media type icon

    ACC-SVN128G-EN_04232020

    Document Title:Discharge Air Sensing Kit Precedent™ Gas Heat with Plenum Fan
    Publication Type:Installation
    Publication Date:2020-04-23
    Sensing KitPrecedent™ Gas Heat with Plenum Fan Model Number: Used With:BAYTUBE400* Precedent D cabinet (digit 30=D) YSC120E/F/H*R, YHC074-102F*R, YSC092-102H (digit 15 = 6 or 7), YZC072-102F*R, DHC074-102 BAYTUBE402* Precedent E cabinet (digit 30=E)YHC092-120E*R, YHC120F*RYZC120F*R, DHC120 Warnings
  • Media type icon

    ACC-SVN132J-EN_04232020

    Document Title:Quick Adapt Roof Curb Adapts the Precedent™ Unit to a Carrier HJ Series Roof Curb
    Publication Type:Installation
    Publication Date:2020-04-23
    cabinet (digit 30 = B or F) to Carrier 74x47 T/YSC036-060G, T/YHC036E, T/YHC037E, T/YZC036E, WSC036-048H, D/WHC036H BAYQACB501* Precedent C/D cabinet (digit 30 = C or D) to Carrier 74x47 T/YSC072-120E/F/H, T/YHC047-074E/F, T/YZC048-072, WSC072-090E, WSC060-120H, D/WHC048-102H BAYQACB502* Precedent C
  • Media type icon

    ACC-SVN36R-EN_04302020

    Document Title:LP Conversion Kit Used with 3 to 10 Tons Two-Stage Gas Packaged Units
    Publication Type:Installation
    Publication Date:2020-04-30
    YZC072F**(H,Z) 150 44.0 DRILL #46 REMOVE YHC074**(H,Z) 150 44.0 DRILL #49 2410 DHC092H**(M,Y) 150 44.0 DRILL #46 REMOVE YZC090F**(M,Y) 150 44.0 DRILL #46 REMOVE YSC090E/F/H**(M,Y) 150 44.0 DRILL #46 0310 YSC092E/F**(M,Y) 150 44.0 DRILL #46 NO CHANGE YSC092H**(M,Y)****(0,1) 150 44.0 DRILL #46 NO CHANGE
  • Media type icon

    ACC-SVN102P-EN_04212020

    Document Title:LP Conversion Kit Used with 3 to 8.5 Ton Packaged Units with Single Stage Gas
    Publication Type:Installation
    Publication Date:2020-04-21
    Drill # 49 no change YSC048E**(H,Z) 120 35.2 Drill # 49 no change YZC048E**(H,Z) 120 35.2 Drill # 49 no change YHC060F1*(L,X) 60 17.6 Drill # 52 0210 YHC060E/F(3,4,W)*(L,X) 60 17.6 Drill # 52 no change YHC067E/F**(L,X) 60 17.6 Drill # 52 no change YSC060E**(L,X) 60 17.6 Drill # 52 no change YZC060E**(L
  • Media type icon

    ACC-SVN43N-EN_04242020

    Document Title:Precedent™ Packaged Rooftop Units Roof Curb
    Publication Type:Installation
    Publication Date:2020-04-24
    (fiops)/accessory net weights (lbs) (a) (b), Net Weights Option/Accessory Description T/YHC036E, T/YHC037E, WSC060ED, T/YZC036E T/YHC048-060F, T/YHC047-067E T/YZC048F, T/YZC060E, T/YZC048-060, WSC060H, D/WHC048-060H T/YSC072-102H,T/YHC072E,T/YHC072F, WSC072-102H T/YSC120H, T/YHC074F, T/YHC092-102F
  • Media type icon

    4366-8508A_08082014

    Document Title:Precedent Wiring Diagram; Ultra High Efficiency eFlex Precedent Connection Diagram - YZC036E3, Variable Speed Compressor
    Publication Type:Wiring Diagram or Manual
    Publication Date:2014-08-08
    DO NOT SCALE PRINT DRAWN BY: THIRD ANGLEPROJECTION CDATE: TRANE REV THIS DRAWING IS PROPRIETARY AND SHALL NOT BECOPIED OR ITS CONTENTS DISCLOSED TO OUTSIDEPARTIES WITHOUT THE WRITTEN CONSENT OF TRANE TRANE D. SHANNON 16-AUG-13 4366-8508 A DIAGRAM CONNECTION PRINT YZC036E3 ULTRA HIGH EFFICIENCY VSC
  • Media type icon

    4366-8509A_08082014

    Document Title:Precedent Wiring Diagram; Ultra High Efficiency eFlex Precedent Connection Diagram - YZC036E4, Variable Speed Compressor
    Publication Type:Wiring Diagram or Manual
    Publication Date:2014-08-08
    DO NOT SCALE PRINT DRAWN BY: THIRD ANGLEPROJECTION CDATE: TRANE REV THIS DRAWING IS PROPRIETARY AND SHALL NOT BECOPIED OR ITS CONTENTS DISCLOSED TO OUTSIDEPARTIES WITHOUT THE WRITTEN CONSENT OF TRANE TRANE D. SHANNON 16-AUG-13 4366-8509 A DIAGRAM CONNECTION PRINT YZC036E4 ULTRA HIGH EFFICIENCY VSC