Search Results: TEMP-SLB008-EN

Showing 81 - 90 of 7,117 results

Display results per page.
  • Media type icon

    MCX6-PRC804-EN_11011998

    Document Title:Stylus Mini-Split System Air Conditioning, 1 - 5 Tons Convertible Models, 60 Hz. Models- MCX512E1, MCX518E1, MCX524E1, MCX536E1, MCX042E1, MCX048E1, MCX060E1
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:1998-11-01
    Rating Conditions of 80/67 & 95 FGROSS CAPACITY: 14.8 MBHAIRFLOW: 400 CFMSYSTEM POWER: 1779 WATTSNOM. SYSTEM AMPS: 8.2 AMPS English Units 21MCX6-PRC804-EN PerformanceDataCooling TTB012C100A WITH MCX512E1AT 680 CMH GROSS CAPACITY IN KILOWATTSO.D. I.D. GROSS SENS. CAP. AT ENTERING D.B. TEMP. COMPR.D.B
  • Media type icon

    ODR-SVX004C-EN_09192025

    5682 0.38 105.00 40.56 5079 0.35 110.00 43.33 4548 0.31 ODR-SVX004C-EN 25 Table 13. Defrost control thermistor (continued) Temp °F Temp °CThermistorResistance(ohms) Volts DC 115.00 46.11 4079 0.28 120.00 48.89 3665 0.26 125.00 51.67 3298 0.23 130.00 54.44 2972 0.21 135.00 57.22 2683 0.19Example
  • Media type icon

    88-A5AC5001-1B-EN_10172024

    Document Title:Condensing Units
    Publication Type:Installation Operation and Maintenance
    Publication Date:2024-10-17
    operating conditions (indoor/outdoor temperatures) are not in range to verify with the subcooling charging method. 88-A5AC5001-1B-EN 14.4 Weigh-In Method for Charging Indoor Wet Bulb Temp (F) Outdoor Dry Bulb Temp.(F) 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 55
  • Media type icon

    BAS-SVP053A-EN_04162022

    Document Title:BACnet® Communication Interface for ReliaTel™ Controllers (BCI2-R)
    Publication Type:Integration Guide
    Publication Date:2022-04-16
    BBAASS--SSVVPP005533AA--EENN Integration Guide BACnet®® Communication Interfacefor ReliaTel™™ Controllers (BCI2-R) ©2022 Trane BAS-SVP053A-EN IntroductionThe BACnet Communication Interface for ReliaTel (BCI2-R) supportsTrane ReliaTel rooftop unitsthat function as part of a BACnet MS/TP communications
  • Media type icon

    BAS-PTS022A-EN_11152024

    Document Title:Symbio™ 800 Integration Points List LonTalk® for Ascend™ Air-Cooled Chiller Model ACR Series C
    Publication Type:Points List
    Publication Date:2024-11-15
    Symbio™ 800 Integration Points ListLonTalk®Ascend™ Model ACR Series C Date: 11/15/2024Reference Document: BAS-SVP084*-EN Profile Definition and Network Variables The following tables are sorted as follows: • Tables are listed by unit/profile type and sorted by network variable number.• Tables are
  • Media type icon

    BAS-SVP085B-EN_11152024

    Document Title:BACnet® and Modbus ™ Integration
    Publication Type:Integration Guide
    Publication Date:2024-11-15
    . If the Heat Cool Mode Status is Cool then the Symbio™ 700 controller will use the Space Temp Cooling Setpoint Status.7. If the Heat Cool Mode Status is Heat then the Symbio™ 700 controller will use the Space Temp Heating Setpoint Status. Appendix A: Arbitrations 24 BAS-SVP085B-EN Space Temperature
  • Media type icon

    BAS-SVN028L-EN_08062022

    Document Title:Trane® Commercial Touch Screen Programmable Zone Sensor for ReliaTel™, UC400 and Symbio™ 400/700/800 Controls
    Publication Type:Installation
    Publication Date:2022-08-06
    wired to HVAC equipment. Important: Configure the Temp Sensor parameter as needed. See 2/4 Configuration menu for details. BAS-SVN028L-EN 7 Zone Sensor Wiring ReliaTel™ SystemsThe zone sensor and the BCI-R form a two-node BACnet MS/TP network. Wire the system as shown in the schematic below while
  • Media type icon

    SSA-PRC006-EN_12012014

    Document Title:Illusion Concealed Type Minisplit Air Conditioners 12,000 - 60,000 Btu/h MCD Series 50 / 60 Hz / Product Bulletin
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2014-12-01
    Performance Data 24 SSA-PRC006-EN Fan Performance Data SSA-PRC006-EN 25 Fan Performance Data TTK509LB5 WITH MCD009AA5 26 SSA-PRC006-EN OUTDOOR I.D. GROSS SENS. CAP. AT ENTERING D.B. TEMP. COMPR.D.B. W.B. CAP. 72 74 76 78 80 KW 61 9.7 7.6 8.3 8.9 9.5 9.9* 0.67 8565 10.5 6.3 7.0 7.6 8.2 8.9 0.7067 10.9 5.6
  • Media type icon

    TEMP-SVX002B-EN_05092025

    an unqualified person could result in death orserious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. May 2025 TEMP-SVX002B-EN Installation, Operation, and MaintenanceTrane Rental ServicesACSA
  • Media type icon

    BAS-SVP047B-EN_09092023

    Document Title:BACnet® and Modbus™ Integration to Agility™ Water-Cooled Chillers with Symbio™ Controls
    Publication Type:Integration Guide
    Publication Date:2023-09-09
    Water Pressure 0 = Normal1 = In Alarm BI-11067 Diagnostic: Evaporator Leaving Water Temp Sensor 0 = Normal1 = In Alarm BACnet Points List BAS-SVP047B-EN 21 Table 4. Binary input diagnostics (continued) Object Identifier Object Name Object States BI-11068 Diagnostic: Evaporator Water Flow