    23116079_A_08232023

    FORWIRE INSERTION INSTRUCTIONS. SPLICE FIELD WIRES TOGETHER ANDWIRE TO 1X6. 11 SETPOINT INPUT SETPOINT INPUT 20 6 9 18 14 19 14 1414 10 26 14 14 14 14 14 21 26 4 21 5 26 29 14 14 29 14 29 14 29 22 2 22 2 11 27 11 27 8 25 7 6 7 30 17 17 CLASS II CLASS I 8 8 28 30 WHEN ORDERED THE OUTDOOR AIR TEMP SENSOR
  • Media type icon

    RT-PRC109C-EN_07152023

    Document Title:Packaged Rooftop Air Conditioners Precedent™ Cooling and Electric Heat Ultra High Efficiency 12.5 to 25 Tons — 60 Hz
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2023-07-15
    airflow performance table for each unit. To calculate temp. rise at different airflow, use the following formula: Temp. rise across Electric Heater = (kW x 3414)/(1.08 x cfm). RT-PRC109C-EN 53 ControlsEnhanced BAS Integration and Connectivity • Symbio™ 700 integrates seamlessly with Trane® Tracer®
  • Media type icon

    CAUK-SVX001B-EN_05082025

    : Minimum starting ambients in degrees F, based on unit at minimum step of unloading and 5 mph wind across condenser. Start-Up 48 CAUK-SVX001B-EN Table19. Samplemaintenance log Date Current Ambient Temp. (°F) Refrig erantC ircuit#1 Refrig erantC ircuit#2 Com pr. Oillevel Suct. Press. (Psig) Disch. Press
  • Media type icon

    RT-SVX078D-EN_10312025

    occur. RT-SVX078D-EN 35 Table 10. FDD troubleshooting Faults Tests Air temp. sensorfailure/fault Not economizingwhen it should Economizing when itshould not Damper notmodulating Excess outdoorair Damper Stuck Open x x x Damper Stuck at Minimum x x Bad or Unplugged Actuator x x x Sensor Hard Failure x x
  • Media type icon

    23116084_A_08232023

    SETPOINT INPUT 20 6 9 18 14 19 14 1414 10 26 14 14 26 14 14 14 14 21 26 4 21 5 26 14 29 22 2 22 2 14 22 11 27 11 27 8 25 7 6 7 30 17 17 CLASS II CLASS I 8 8 28 30 WHEN ORDERED THE OUTDOOR AIR TEMP SENSOR ELECTRONICS IS FACTORY MOUNTED INSIDETHE CONTROL PANEL AND THE IPC BUS IS FACTORY WIRED. THE
  • Media type icon

    UNT-PRC001AA-EN_02262026

    air X Generic X 24 UNT-PRC001AA-EN Table 5. Controller function summary Control functions UC400-B/Symbio™ 400-B Entering water temp. sampling (purge) X Timed override X Auto changeover X Fan cycling X Warm-up X Pre-cool X Data sharing (client/server) – Random start X Dehumidification – Air-Fi®
  • Media type icon

    1213-4443B_03302022

    Document Title:Precedent™ SCHEMATIC; SHEET 4, CONTROLS, ADAPTER BOARD UNIT CONTROLS, DUAL COMPRESSOR, SINGLE FAN
    Publication Type:Wiring Diagram or Manual
    Publication Date:2022-03-30
    LEGENDREF DES DESCRIPTION LINE NOAB MODULE - ADAPTER BOARD 201CC1 CONTACTOR - COMPRESSOR 1 191CC1 (AUX2) CONTACTOR - COMPRESSOR 1 AUX 2 187CC2 CONTACTOR - COMPRESSOR 2 194CC2 (AUX2) CONTACTOR - COMPRESSOR 2 AUX 2 189DTL1 SWITCH - DISCHARGE TEMP LIMIT 1 202DTL2 SWITCH - DISCHARGE TEMP LIMIT 2
  • Media type icon

    1213-4444B_02022022

    Document Title:Precedent™ SCHEMATIC; SHEET 4, CONTROLS, ADAPTER BOARD UNIT CONTROLS, DUAL COMPRESSOR, DUAL FAN
    Publication Type:Wiring Diagram or Manual
    Publication Date:2022-02-02
    LEGENDREF DES DESCRIPTION LINE NOAB MODULE - ADAPTER BOARD 201CC1 CONTACTOR - COMPRESSOR 1 191CC1 (AUX2) CONTACTOR - COMPRESSOR 1 AUX 2 187CC2 CONTACTOR - COMPRESSOR 2 194CC2 (AUX2) CONTACTOR - COMPRESSOR 2 AUX 2 189CUS2 SOLENOID - CMPR 2 UNLOADING 215DTL1 SWITCH - DISCHARGE TEMP LIMIT 1 202DTL2
  • Media type icon

    KIT00863_08012006

    Document Title:KIT00863 KIT; RECEIVER CONTROLLER
    Publication Type:Installation
    Publication Date:2006-08-01
    SHEET .030 X 24, (2000 FEET) STK RAW 8/13/1990 0 Linear InchTRM00003 TRANSMITTER; CNT TEMP, 0-100F, W/WELL 3FT. CAPILLARY TUBE STK FINISH 7/9/1998 1 EACHX18120372020 BOX; RESHIP CONTAINER 14.5IN.L X 7.9IN.W X 7.4IN.H STK RAW 1/18/1994 1 EACHCNT00778 CONTROL;RECEIVER,40-120F CAN BE REPLACED BY DIGITAL
  • Media type icon

    RT-PRC122C-EN_11152025

    Heat Yes Yes Yes Yes 8 ft. Blank Section Horizontal - Left Side - FieldConvertible Cooling Only, Steam Heat,Hot Water Heat Field Convert Yes Yes Yes 8 ft. Blank Section Downflow - Standard Option Gas(a) or Electric(b) Yes No High Temp High Temp Application Considerations RT-PRC122C-EN 27 Table 1