Search Results: TEMP-PRC013A-EN

Showing 61 - 70 of 7,172 results

Display results per page.
  • Media type icon

    22-1633-04_12011996

    11.00 RATINGS (HEATING) 1 (HIGH TEMP.) BTUH 28400 28400 27800 28800 29200 29200 28800SYSTEM POWER (KW) 2.51 2.51 2.59 2.51 2.47 2.47 2.51COP 3.32 3.32 3.14 3.36 3.46 3.46 3.36 HSPF (BTU/WATT-HR.) 7.65 7.65 7.35 7.65 7.80 7.80 7.65 GeneralData 13Pub. No. 22-1633-04-1296 (EN) TWN030C100A OUTDOOR UNIT
  • Media type icon

    18-HD82D1-1E-EN_09162021

    - ODT (outdoor temperature sensor). If ODT sensor is selected and connected, the outdoor temp is displayed on the main screen. ODT model is BAYSEN01ATEMPA. RS RS ODT ODT Outdoor Sensor Remote Sensor Optional Remote Temperature Sensor Installation XR724 INSTALLER’S GUIDE 38 18-HD82D1-1E-EN
  • Media type icon

    BAS-PTS026A-EN_12062024

    Inputs 3 Symbio™ 800 Integration Points ListBACnet®ACSA (UC800) Date: 12/6/2024Reference Document: BAS-SVP083*-EN Object Identifier Object Name Description Units Configuration Dependency 51 Starts Cprsr2A Real52 Run Time Cprsr2A Real69 Heat Recovery Entering Water Temp Real70 Heat Recovery Leaving
  • Media type icon

    BAS-PTS025A-EN_12062024

    Diagnostics 10 Symbio™ 800 Integration Points ListBACnet®ACRB Small (UC800) Date: 12/06/2024Reference Document: BAS-SVP083*-EN Object Identifier Object Name Object States 11031 Diagnostic: Evap Rfgt Pool Temp Sensor Error - Ckt1 0= Normal1= In Alarm 11032 Diagnostic: Evap Rfgt Pool Temp Sensor Error - Ckt2 0
  • Media type icon

    BAS-PTS008A-EN_11152024

    Symbio™ 800 Integration Points List LonTalk®Agility™ Water-cooled Chillers Date: 11/15/2024 Reference Document: BAS-SVP084*-EN Profile Definition and Network Variables The following tables are sorted as follows: • Tables are listed by unit/profile type and sorted by network variable number
  • Media type icon

    BAS-PTS023A-EN_11082024

    Document Title:Symbio™ 800 Integration Points List BACnet®/Modbus™ for Series R® Air- Cooled Chiller Model RTAC
    Publication Type:Points List
    Publication Date:2024-11-08
    -11100 Comm Loss: Cprsr Disch Rfgt Temp - 1A0 = Normal1 = In Alarm 34101 BAS-PTS023A-ENBinary Inputs 16 Symbio™ 800 Integration Points ListBACnet®/Modbus™RTAC Date: 11/8/2024Reference Document: BAS-SVP083*-EN BACnetObject Identifier Object Name Description Configuration Dependency Modbus Register
  • Media type icon

    BAS-PTS019A-EN_11152024

    Document Title:Symbio™ 800 Integration Points List BACnet®/Modbus™ for Air-Cooled Chiller Model CGAM
    Publication Type:Points List
    Publication Date:2024-11-15
    Evaporator Water Temperature BAS-PTS019A-ENDiagnostic Hex Codes 54 Symbio™ 800 Integration Points ListBACnet®/Modbus™CGAM Date:11/15/2024Reference Document: BAS-SVP083*-EN Diagnostic Code (Decimal) Diagnostic Name 111007 Comm Loss: Evaporator Antifreeze Heater111010 Inverted Water Temp (Heating)111011 High
  • Media type icon

    DL-SVX004A-XX_11012018

    Document Title:Trane - Mitsubishi Split-System Heat Pump, Models NTXCKS09A112A*, NTXCKS12A112A*, NTXCKS15A112A*, NTXCKS18A112A* / Installation Operation and Maintenance
    Publication Type:Installation Operation and Maintenance
    Publication Date:2018-11-01
    CoolRoom Set temp. Mode Temp. Fan Fri Presione el botón [F4] para ver las velocidades del ventilador en el si-guiente orden. Auto Notas: ● El número de velocidades del ventilador disponibles depende del tipo de unidad conectada. ● En los siguientes casos, la velocidad real del ventilador generada por la
  • Media type icon

    PART-PRC010A-EN_05062025

    Document Title:R-410A Scroll Compressor Models CSHN and CSHL 15 to 30 Tons
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2025-05-06
    268,588 320,148 140 — — — 132,506 165,761 203,880 224,770 246,878 294,724 150 — — — 118,950 149,303 184,141 203,250 223,483 267,298 Performance Data PART-PRC010A-EN 13 Table 4. Capacity (btu/hr) — voltage 230-60-3 (continued) Compressor CondTemp °F Evaporator Temp °F -10 0 10 20 30 40 45 50 60 CSHN315 80
  • Media type icon

    BAS-PTS028A-EN_12062024

    Water Setpoint Temp BAS-PTS028A-ENInput Registers 20 Symbio™ 800 Integration Points ListModbus™HDWA (UC800) Date: 12/6/2024Reference Document: BAS-SVP083*-EN Register Address Object name Description Register Type Register Value Valid Range 30042 External Demand Limit Setpoint Percent30043 Front Panel