Search Results: ED*

Showing 541 - 550 of 1,448 results

Display results per page.
  • Media type icon

    PKGR-PSD005B-EN_09102025

    Document Title:Single Packaged Gas/Electric, Choice, Convertible, 2 to 5 Ton, R-454B
    Publication Type:Product and Submittal Data
    Publication Date:2025-09-10
    Figure 22. Bottom and back duct openings I J J L M G B ED F E C K H N Table 22. Dimensions (mm [inch]) Model Height-A B C D E F G H I J K L M N 5YCC4024898.53[35-3/8] 304.80[12] 75.41[2.93] 75.41[2.93] 406.40[16] 167.89[6.61] 173.46[6.84] 304.80[12] 79.50[3.13] 398.22[15.68] 176.07[6.93] 177.55[6.99
  • Media type icon

    PKGR-PSD014B-EN_09102025

    Document Title:Single Packaged Gas/Electric Entry, Convertible, 2 to 5 Ton, R-454B
    Publication Type:Product and Submittal Data
    Publication Date:2025-09-10
    - See Table 3 22 PKGR-PSD014B-EN Figure 14. Bottom and back duct openings I J J L M G B ED F E C K H N Table 13. Dimensions (mm [inch]) Model Height-A B C D E F G H I J K L M N A5PG3024898.53[35 - 3/8] 304.80 [12.0]75.41[2.97] 75.41[2.97] 406.40[16.0] 167.89[6.61] 173.46[6.8] 304.80[12.0] 79.50[3.13
  • Media type icon

    AHR-SVN003A-EN_09202025

    Document Title:Single Point Power Entry Kit
    Publication Type:Installation
    Publication Date:2025-09-20
    supportcould result in unit falling from its location whichcould result in death or serious injury.Ceiling structure must be strong enough to supportthe weight of the unit and any accessories. If unsure,check with a structural engineer. CAUTIONSharp Edges!Failure to follow instructions below could
  • Media type icon

    PKGR-SVX001C-EN_10062025

    Document Title:Installation and Operations Manual - Single Packaged Gas/Electric, Priority, 2 - 5 Ton, 60 - 115 KBTU, R-454B, 5YCZ5
    Publication Type:Installation
    Publication Date:2025-10-06
    ://www.p65warnings.ca.gov/ https://www.p65warnings.ca.gov/ 4 PKGR-SVX001C-EN CAUTIONSharp Edges!Failure to follow instructions below could result inminor to moderate injury.The service procedure described in this documentinvolves working around sharp edges. To avoid beingcut, technicians MUST put on all
  • Media type icon

    PKGR-SVX003C-EN_10062025

    Document Title:Single Packaged Heat Pump, Choice, Convertible, 2 - 5 Ton, R-454B, 5WCC4
    Publication Type:Installation
    Publication Date:2025-10-06
    or equipment damage.The unit is equipped with electrically powered safetymeasures and must be powered at all times afterinstallation, except during servicing, to detect anyleak. Introduction https://www.p65warnings.ca.gov/ https://www.p65warnings.ca.gov/ 4 PKGR-SVX003C-EN CAUTIONSharp Edges!Failure
  • Media type icon

    PKGR-SVX008B-EN_10062025

    Document Title:Installation and Operations Manual - Single Packaged Cooling/Electric Heat, Choice, Convertible, 2 – 5 Ton, R-454B, 5TCC4
    Publication Type:Installation
    Publication Date:2025-10-06
    safetymeasures and must be powered at all times afterinstallation, except during servicing, to detect anyleak. Introduction https://www.p65warnings.ca.gov/ https://www.p65warnings.ca.gov/ 4 PKGR-SVX008B-EN CAUTIONSharp Edges!Failure to follow instructions below could result inminor to moderate injury.The
  • Media type icon

    PKGR-SVX009B-EN_10062025

    Document Title:Installation and Operations Manual - Single Packaged Cooling/Electric Heat, Entry, Convertible, 2-5 Ton, R-454B, A5PA
    Publication Type:Installation
    Publication Date:2025-10-06
    safetymeasures and must be powered at all times afterinstallation, except during servicing, to detect anyleak. Introduction https://www.p65warnings.ca.gov/ https://www.p65warnings.ca.gov/ 4 PKGR-SVX009B-EN CAUTIONSharp Edges!Failure to follow instructions below could result inminor to moderate injury.The
  • Media type icon

    PKGR-SVX010B-EN_10062025

    Document Title:Installation and Operations Manual - Single Packaged Heat Pump, Entry, Convertible, 2-5 Ton, A5PH
    Publication Type:Installation
    Publication Date:2025-10-06
    must be powered at all times afterinstallation, except during servicing, to detect anyleak. Introduction https://www.p65warnings.ca.gov/ https://www.p65warnings.ca.gov/ 4 PKGR-SVX010B-EN CAUTIONSharp Edges!Failure to follow instructions below could result inminor to moderate injury.The service
  • Media type icon

    PKGR-SVX011B-EN_10062025

    Document Title:Single Packaged Gas/Electric, Entry, Convertible, 2 - 5 Ton, R-454B, A5PG
    Publication Type:Installation
    Publication Date:2025-10-06
    and must be powered at all times afterinstallation, except during servicing, to detect anyleak. Introduction https://www.p65warnings.ca.gov/ https://www.p65warnings.ca.gov/ 4 PKGR-SVX011B-EN CAUTIONSharp Edges!Failure to follow instructions below could result inminor to moderate injury.The service
  • Media type icon

    AHR-SVX002B-EN_10132025

    Document Title:Convertible Air Handlers 1-1/2 – 5 Ton
    Publication Type:Installation Operation and Maintenance
    Publication Date:2025-10-13
    returned to theiroriginal position and properly fastened. CAUTIONSharp Edges!Failure to follow instructions below could result inminor to moderate injury or property damage.Be careful of sharp edges on equipment or any cutsmade on sheet metal while installing or servicing. CAUTIONCorrosion Hazard