    ACC-SVN327A-EN_07182026

    Document Title:SCR Modulating Electric Heater Conversion
    Publication Type:Installation
    Publication Date:2026-07-18
    matrix Unit Size(Tons) Model Number Digits 4, 5, 6Model TSK, YSK THK, YHK TZK, YZK WSK, DSK WHK, DHK 3 036 A.0 A.0 B.0 A.0 B.0 4 048 B.0 5 060 6 072 B.0B.07.5 090 8.5 102 10 120 C.0 B.0, C.0(a) C.0 12.5 150 C.0 C.0 D1 D.0 D.015 180 D.0 D.017.5 210 20 240D.1 D.1 25 300 (a) A cabinet size change was made
  • Media type icon

    AHR-PSD014A-EN_06202025

    Document Title:Trane Modular Blowers - No Heat P0V0
    Publication Type:Product and Submittal Data
    Publication Date:2025-06-20
    3/4 1 1 R.P.M. Variable Variable Variable Variable Volts / Ph / Hz 120 / 1 / 60 120 / 1 / 60 120 / 1 / 60 120 / 1 / 60 FLA 6.4 9.6 10.0 10.0 Filter — Furnished? No No No No Type Recommended High Velocity High Velocity High Velocity High Velocity Hi Vel. (No.-Size-Thk.) 1 - 14 X 25 - 1 in. 1 - 16 X
  • Media type icon

    FNR-PSD009C-EN_02272026

    Document Title:Upflow/Horizontal Left/Right, Dedicated Downflow Two Stage Condensing Gas Fired Furnace
    Publication Type:Product and Submittal Data
    Publication Date:2026-02-27
    S9V2B040U3VSBB (a) S9V2B060U4VSBB (a) S9V2B080U4VSBB (a) S9V2C080U5VSBB (a) S9V2C100U5VSBB (a) S9V2D120U5VSBB (a) Filter - Furnished? No No No No No No Type Recommended High Velocity High Velocity High Velocity High Velocity High Velocity High Velocity Hi Vel. (No.-Size-Thk.) 1 - 16 x 25 - 1 in. 1 - 16 x 25 - 1
  • Media type icon

    41-5016-12_03012011

    Document Title:INSTALLATION, OPERATION, AND MAINTENANCE GUIDE - Upflow / Horizontal* and Downflow / Horizontal*, Single Stage Direct Vent Gas-Fired Condensing Furnaces Models: CUX1, CDX1
    Publication Type:Installation
    Publication Date:2011-03-01
    - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / HzCOMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLAFILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)VENT — Size (in.)HEAT EXCHANGERType -Fired -UnfiredGauge (Fired)ORIFICES — MainNat. Gas. Qty
  • Media type icon

    FNR-PSD001A-EN_07012025

    Document Title:Upflow/Horizontal Left/Right Gas-Fired, Single Stage Induced Draft Furnace with High Efficiency Variable Speed Blower Motor
    Publication Type:Product and Submittal Data
    Publication Date:2025-07-01
    3.15 3.15Filter – Furnished? No No No NoType recommended High Velocity High Velocity High Velocity High VelocityHigh Vel. (No.–Size–Thk.) 1 – 14 x 25 – 1 in. 1 – 14 x 25 – 1 in. 1 – 16 x 25 – 1 in. 1 – 20 x 25 – 1 in.Vent Pipe Diameter – Min (in.) (e) 4 Round 4 Round 4 Round 4 RoundHeat Exchanger
  • Media type icon

    ACC-SVN228F-EN_07182026

    Document Title:Electric Heaters – Precedent™ Packaged Rooftop Units 3 to 25 Tons
    Publication Type:Installation
    Publication Date:2026-07-18
    NumberDigits 4, 5, 6 Model TSK, YSK THK, YHK TZK, YZK WSK, DSK WHK, DHK 3 036 A.0 A.0 B.0 A.0 B.0 4 048 B.0 5 060 6 072 B.0B.07.5 090 8.5 102 10 120 C.0 B.0, C.0(a) C.0 12.5 150 C.0 D.0 D.1 D.0 D.015 180 D.0 D.017.5 210 20 240 D.1 D.1 25 300 D.1 D.1 (a) A cabinet size change was made in 2025. Please
  • Media type icon

    22-1806-04_04012009

    Document Title:Trane Communicating Only Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent 3 Stage Gas Furnace with Variable Speed Inducer TUH3 and TDH3
    Publication Type:Product Data
    Publication Date:2009-04-01
    (ICS) 3Temp. rise (Min.-Max.) °F.AFUEBLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / HzCOMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLAFILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)VENT — Size (in.)HEAT EXCHANGERType
  • Media type icon

    FNR-PSD005A-EN_07012025

    Document Title:Link Communicating or 24 Volt Gas-Fired 2 Stage Induced Draft Furnaces with Variable Speed Motor
    Publication Type:Product and Submittal Data
    Publication Date:2025-07-01
    / 60 120 / 1 / 60FLA 0.30 0.30 0.33Inducer Orifice 1.20 1.40 1.75Filter - Furnished? No No NoType Recommended High Velocity High Velocity High VelocityHi Vel. (No.-Size-Thk.) 1 - 14 X 25 - 1 in. 1 - 16 X 25 - 1 in. 1 - 16 X 25 - 1 in.Vent Pipe Diameter - Min. (in.)(e) 4 Round 4 Round 4 RoundHeat
  • Media type icon

    FNR-SVX002A-EN_02232026

    Document Title:Installation, Operation, and Maintenance - Upflow/Horizontal and Downflow Gas-Fired, Direct/Non-Direct Vent, Single Stage/Two Stage Condensing Furnaces with High Efficiency Motor S9X1, S9X2, S9B1
    Publication Type:Installation Operation and Maintenance
    Publication Date:2026-02-23
    /Ph/Hz 120 / 1 / 60 120 / 1 / 60 120 / 1 / 60 120 / 1 / 60 FLA 2.1 2.1 2.1 0.7 Filter - Furnished? No No No No Type Recommended High Velocity High Velocity High Velocity High Velocity Hi Vel. (No.-Size-Thk.) 1 - 16 X 25 - 1 in. 1 - 16 X 25 - 1 in. 1 - 16 X 25 - 1 in. 1 - 20 X 25 - 1 in. FNR-SVX002A
  • Media type icon

    S8XB-SVX001-1D-EN_08092024

    Document Title:Installation, Operation, and Maintenance Upflow/Downflow/Horizontal Gas-Fired, 1-Stage and 2-Stage Induced Draft Furnaces with High Efficiency Motor S8B1, S8X1, S8X2 - Q Models
    Publication Type:Installation Operation and Maintenance
    Publication Date:2024-08-09
    / 60 120 / 1 / 60 120 / 1 / 60 120 / 1 / 60 FLA 0.30 0.30 1.40 1.40 Inducer Orifice 1.20 1.15 1.40 2.15 FILTER - Furnished? No No No No Type Recommended High Velocity High Velocity High Velocity High Velocity Hi Vel. (No.-Size-Thk.) 1 - 14 X 25 - 1 in. 1 - 16 X 25 - 1 in. 1 - 16 X 25 - 1 in. 1 - 16 X