    PART-SVN252A-EN_05192021

    Document Title:Crankcase Heaters - Model H Compressors Part Information HTR01225, HTR01226, HTR01227 / Installation Instructions
    Publication Type:Installation
    Publication Date:2021-05-19
    by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. ©2021 Trane May 2021 PART-SVN252A-EN Installation Instructions Crankcase Heaters - Model
  • Media type icon

    5722-9583A_02222022

    Document Title:RTAF Component Location Diagram 280-520T
    Publication Type:Wiring Diagram or Manual
    Publication Date:2022-02-22
    PARA ACEPTAROTROS TIPOS DE CONDUCTORES. NO REALIZAR LO ANTEDICHO PUEDEPROVOCAR DAÑOS EN EL EQUIPO. AVISN'UTILISER QUE DES CONDUCTEURS EN CUIVRE!LES BORNES DE L'UNITÉ NE SONTPAS CONÇUES POUR RECEVOIR D'AUTRES TYPES DE CONDUCTEURS.UN MANQUEMENT À LA PROCÉDURE CI-DESSUS PEUT ENTRAÎNERDES DOMMAGES À
  • Media type icon

    RT-PRC122C-EN_11152025

    Document Title:Packaged Rooftop Air Conditioners IntelliPak™ 2 90 – 150 Tons — Air-Cooled Condensers
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2025-11-15
    and the Humidification output are de-energized forany Emergency Override sequence. Each Emergency Override sequence commands the unit operation as follows: Symbio™ 800 Controls 18 RT-PRC122C-EN PRESSURIZE_EMERG:• Supply Fan - On• Supply Fan VFD - Max• Relief Fan - Off; Relief Dampers - Closed (if so
  • Media type icon

    ACC-SVN31C-EN_04172020

    Document Title:Anti Short Cycle Timer Kit and Time Delay Relay Kit
    Publication Type:Installation
    Publication Date:2020-04-17
    Figure 4. Wire 412 goes to the terminal strip or low voltage leads. Wire 411 splices to the wire to the stage 2 compressor contactor circuit. 6. Replace and secure both access panels and restore power to the unit. April 2020 ACC-SVN31C-EN Installation Instructions Anti Short Cycle Timer Kit and Time
  • Media type icon

    ACC-SVN11N-EN_06032020

    Document Title:Ventilation Override Kit Used with 3 to 10 Ton Packaged Units with ReliaTel™ Controls
    Publication Type:Installation
    Publication Date:2020-06-03
    /tagout procedures to ensure the power cannot be inadvertently energized. Verify with an appropriate voltmeter that all capacitors have discharged. For additional information regarding the safe discharge of capacitors, see PROD-SVB06A-EN 1. Remove access panels as shown in Figure 3 and Figure 4.Note
  • Media type icon

    ACC-SVN285A-EN_09152024

    Document Title:0 to 25% Manual Fresh Air Damper Precedent™ Packaged Rooftop Units 12.5 to 25 Tons
    Publication Type:Installation
    Publication Date:2024-09-15
    (Digit 39 = D) Installation Instructions 0 to 25% Manual Fresh Air DamperPrecedent™ Packaged Rooftop Units12.5 to 25 Tons September 2024 ACC-SVN285A-EN 1 Warnings, Cautions, and NoticesRead this manual thoroughly before operating or servicing this unit. Safety advisories appear throughout this manual
  • Media type icon

    KIT01348_08012006

    Document Title:KIT01348 KIT; COMP. CHANGEOUT GASKET & O-RING, RTHA 130/150T
    Publication Type:Installation
    Publication Date:2006-08-01
    EACH X23130078330 RING;O, 2.859 ID X .139 RD NLA 11/8/1990 3/26/1996 1 EACHX39000671010 LABEL; TRANE 2 X 3 STK RAW 2/28/2002 0 EACHX18210291010 BAG; AUTO, 9 X 12 X 3MIL, WHITE FRONT/TRANSPARENT BACK STK RAW 6/13/2002 0 EACHX18070032020 BOX; 13.00 X 13.00 X .63 STK RAW 1/18/1994 1 EACH276400183300
  • Media type icon

    ADV-SLB023-EN_06182020

    Document Title:Trane Building Advantage - Trane Energy Market Intelligence - Making sense of energy markets
    Publication Type:Sales Brochure
    Publication Date:2020-06-18
    and supply. For more information, please visit trane.com or tranetechnologies.com. © 2020 Trane. All Rights Reserved. Lit # Placeholder 0123456789 All trademarks referenced in this document are the trademarks of their respective owners. ADV-SLB023-EN06/18/2020
  • Media type icon

    ACC-SVN154E-EN_12032022

    Document Title:0 to 50% Motorized Outside Air Damper Foundation™ Packaged Rooftop Units 15 to 25 Tons
    Publication Type:Installation
    Publication Date:2022-12-03
    2022 ACC-SVN154E-EN 9 1110 12 8 ©2022 Trane and American Standard have a policy of continuous product and product data improvement and reserve the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. Trane and American Standard
  • Media type icon

    MCD5-MAIR03-EN_11012004

    Document Title:Illusion Split System - Split System Air Conditioning (Concealed Type) 1-5 Ton - 50 Hz
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2004-11-01
    = Cooling Only Digit 3 - Configuration D = Concealed Digit 4 - Refrigerant Connection 5 = Flare0 = Brazed Digit 5,6 = Nominal Capacity12 = 12 MBh 18 = 18 MBh24 = 24 MBh30 = 30 MBh36 = 36 MBh48 = 48 MBh60 = 60 MBh Digit 7 D = Development Sequence Digit 8 - VoltageB = 220-240/1/501 = 220-240/1/60 Digit 9