    TEMP-SVN012A-EN_04262025

    value setting. • Depending on the fan selection switch position on the control cabinet door fan mode is VFD or BYPASS (soft start). Modes of Operation 18 TEMP-SVN012A-EN Mode Sequence of Operation LEAD/FOLLOW • Units ship with a yellow communication cable (field-installed). The cable has two, five
  • Media type icon

    TEMP-PRC009A-EN_04152025

    Document Title:Trane Rental Services - Temporary Water-Cooled Chillers
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2025-04-15
    Type Star/Wye-Delta LRAY 624 A Table 21. Dimensions and weights Labels ValueLength 20 ft. Width 7 ft. 6 in. Height 9 ft. 6 in. Shipping Weight 19,000 lbs Operating Weight 21,513 lbs 18 TEMP-PRC009A-EN 225 to 1000 Tons CVHF Lifting Device Crane Table 22. Installed/Operating clearances Labels
  • Media type icon

    BAS-SVN223D-EN_01312022

    Document Title:Symbio® 210 Bypass Damper Controller / Installation Instructions
    Publication Type:Installation
    Publication Date:2021-01-31
    Damper Controller January 2021 BAS-SVN223D-EN Order Number: Description:BMSY210ACA0T00011 Symbio 210 MS/TP Programmable Bypass Controller with Trane actuatorBMSY210ACA0T10011 Symbio 210 MS/TP Programmable Bypass Controller with Trane actuator and duct temperature sensor501897940100 VAV controls metal
  • Media type icon

    12134549_C_04102023

    Document Title:PRECEDENT UNIT SCHEMATIC; SHEET 1 POWER, DUAL COMPRESSER WSHP HIGH SCCR
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-04-10
    . FAILURE TO DO SO MAY CAUSE DAMAGE TO THEEQUIPMENT. CAUTION¡UTILICE ÚNICAMENTE CONDUCTORES DE COBRE! LAS TERMINALES DE LA UNIDAD NO ESTÁN DISEÑADASPARA ACEPTAR OTROS TIPOS DE CONDUCTORES. SI NO LO HACE, PUEDE OCASIONAR DAÑO AL EQUIPO. N'UTILISER QUE DES CONDUCTEURS EN CUIVRE! LES BORNES DE L'UNITÉ NE
  • Media type icon

    1213-4992B_10222024

    Document Title:SCHEMATIC; SHEET 1, POWER, SINGLE COMPRESSOR, SINGLE CONDENSER FAN, HIGH SCCR
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-10-22
    CONDUCTORES DE COBRE! LAS TERMINALES DE LA UNIDAD NO ESTÁN DISEÑADASPARA ACEPTAR OTROS TIPOS DE CONDUCTORES. SI NO LO HACE, PUEDE OCASIONAR DAÑO AL EQUIPO. N'UTILISER QUE DES CONDUCTEURS EN CUIVRE! LES BORNES DE L'UNITÉ NE SONT PAS CONÇUESPOUR RECEVOIR D'AUTRES TYPES DE CONDUCTEURS. L'UTILISATION DE
  • Media type icon

    BAS-PTS001B-EN_09052025

    ), for CVZT/VVZT systems. System Type Configured as CVZT/VVZT and Outside Air is configured as 0-100% Write NA 2 % 0.1 100 0 Holding 40160 40161 BAS-PTS001B-EN Analog Inputs 18 Symbio 700 Integration Points List BACnet®/ModbusPrecedent®, Axiom™ Rooftop WSHP Date:09/05/2025 Firmware Release:V7.03.0017
  • Media type icon

    ACC-SVN168G-EN_08232024

    Document Title:Oversized Motor Kit Foundation™ Packaged Rooftop Units 15 to 25 Tons
    Publication Type:Installation
    Publication Date:2024-08-23
    to secure the motor leads to the cabinet.18.Replace the access panel and close the unit disconnect switch. WARNING Live Electrical Components!Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. When it is necessary
  • Media type icon

    PART-SVN227B-EN_06252020

    Document Title:Voyager Light Commercial Constant Volume to Single Zone Variable Air Volume or Multispeed Conversion / Installation Instructions
    Publication Type:Installation
    Publication Date:2020-06-25
    Voyager Light Commercial Constant Volume to Single Zone Variable Air Volume or Multispeed Conversion Installation Instructions June 2020 PART-SVN227B-EN Models: TCD, TCH, TFD, TFH, YCD, YCH, YFD, YFH, TSD, TSH, THD, THH, YSD, YSH, YHD, YHH SAFETY WARNINGOnly qualified personnel should install and
  • Media type icon

    5071-2739A_01302021

    Document Title:CenTraVac® Schematic Symbio800 CVRF Panel Upgrade Single Door with Optional HGBP or FRCL
    Publication Type:Wiring Diagram or Manual
    Publication Date:2021-01-30
    CONDENSADOR. LESIONES PERSONALES. EN CUIVRE! ATTENTION TYPES DE CONDUCTEURS. PEUT ENDOMMAGER L'蒕UIPEMENT. LES BORNES DE L'UNITÉ NE SONT L'UTILISATION DE TOUT AUTRE CONDUCTEUR PAS CON荱ES POUR RECEVOIR D'AUTRES N'UTILISER QUE DES CONDUCTEURS DAMAGE TO THE EQUIPMENT. USE COPPER CONDUCTORS ONLY! FAILURE
  • Media type icon

    5071-2740A_01302021

    Document Title:CenTraVac® Schematic Symbio800 CVRF Panel Upgrade Double Door with Optional HGBP or FRCL
    Publication Type:Wiring Diagram or Manual
    Publication Date:2021-01-30
    CONDENSADOR. LESIONES PERSONALES. EN CUIVRE! ATTENTION TYPES DE CONDUCTEURS. PEUT ENDOMMAGER L'蒕UIPEMENT. LES BORNES DE L'UNITÉ NE SONT L'UTILISATION DE TOUT AUTRE CONDUCTEUR PAS CON荱ES POUR RECEVOIR D'AUTRES N'UTILISER QUE DES CONDUCTEURS DAMAGE TO THE EQUIPMENT. USE COPPER CONDUCTORS ONLY! FAILURE