Search Results: VAV-SLB018-EN

Showing 161 - 170 of 7,117 results

Display results per page.
  • Media type icon

    22-8301-35_4Q_06242022

    -8301-35 Voyager 2 Packaged SystemsFeatures and Benefits Ligh t Com mer cial V oyag er P acka ged Sys tem s ONLINE O NLY C OPY RT-PRC028AH-EN 13 Features and Benefits Single zone VAV is designed for use in single zone applications like gymnasiums, auditoriums, manufacturing facilities, retail box
  • Media type icon

    RT-SLB054-EN_09252024

    Modulating Hot Gas Reheat (HGRH) — Available on all next-generation Precedent® units. Controlled by space dew point or relative humidity, modulating HGRH helps to maintain consistent, comfortable temperature and humidity. Single-Zone and True Multiple-Zone VAV — For zoned rooftop systems, our single
  • Media type icon

    12134529_B_12122022

    Document Title:CONTROLS - ADAPTER BOARD UNIT CONTROLS |THREE COMPRESSORS (eSTAGE), 3/4 FANS
    Publication Type:Wiring Diagram or Manual
    Publication Date:2022-12-12
    RESS OR 1 RUN OUT COMP RESS OR 2 RUN OUT COMP RESS OR 3 RUN OUT GND- C GND- C GND- A (RED) (BLACK)(BLACK) (BLACK) (YELLOW) (YELLOW) IMC IMCALTERNATE ALTERNATE FAN CONTROLS CONTROLS INDOOR FAN RUNSTATUS/COMMAND VAV RELAY CONDENSER COMPRESSOR COMPRESSOR 1 ENABLE OUT COMPRESSOR 2 ENABLE OUT COMPRESSOR
  • Media type icon

    RT-PRC023AY-EN_12202022

    product's warranty will not be affected. (a) BAYLSDR009A(b) BAYHSMT400A(c) Field Supplied AK56 x 1" Fan Sheave Evaporator Fan Performance — Standard Efficiency 100 RT-PRC023AY-EN Table 62. Direct drive evaporator fan performance – 7.5 tons standard efficiency Title 24 single zone VAV—TSC092H3,4,W
  • Media type icon

    SYS-SLB006-EN_07172020

    outdoor conditions, comparative enthalpy economizer, parallel fan-powered VAV terminals, optimized supply duct static pressure control (fan-pressure optimization). Conventional Systems: Waterside: 10°F ΔT across evaporator, 10°F ΔT across condenser, minimum 90.1 chiller efficiency. Airside: 55°F design
  • Media type icon

    BAS-PTS003C-EN_12172025

    Document Title:Symbio™ 800 Integration Points List BACnet®/Modbus™ for IntelliPak™
    Publication Type:Points List
    Publication Date:2025-12-17
    Symbio™ 800 Integration Points List BACnet®/Modbus™IntelliPak™ Date: 12/17/2025 Firmware Release: 62000663-4-20-0006 Reference Document: BAS-SVP083*-EN Object Naming Conventions The communicated points for the Symbio™ controllers are generally named according to their function. While many of the
  • Media type icon

    SO-SVN024A-EN_08312023

    Document Title:Variable Frequency Drive Conversion TR1 to TR200 IntelliPak™ I and II and Voyager™ 3 only
    Publication Type:Installation
    Publication Date:2023-08-31
    SO-SVN024-EN.book Variable Frequency DriveConversion TR1 to TR200IntelliPak™ 1 and 2 and Voyager™ 3 only Installation Instructions August 2023 SO-SVN024A-EN Model Numbers: Only Clarksville built units with factory installed VFDs. This includes the following Voyager 3commercial units with the VAV
  • Media type icon

    EDU-SLB029-EN_07042020

    Document Title:Geothermal - Distributed or Central Geothermal Systems - It's Your Choice
    Publication Type:Sales Brochure
    Publication Date:2020-07-04
    In or near occupied space In mechanical equipment room Method of distributing air to space Terminal units (one heat pump per space) Air handlers and VAV boxes, one or more Geothermal loop temperatures 40° – 90°F 40° – 140°F Number of loops within the building One One or two Economizer Water Air or
  • Media type icon

    SS-SVX016D-EN_03142026

    = Generation B Digit 15 — Controls 1 = Constant VolumeC = 2 Stage Airflow (Electromechanical Cond Only)D = 2 Stage Airflow/Single Zone VAV (SymbioCond Only) Digit 16 — Indoor Fan Sizes 0 = Standard Motor4 = High Static – (Oversized Motor for VFD Units) Digit 17 to 40 — None 0 = None 6 SS-SVX016D-EN General
  • Media type icon

    BAS-SLB110-EN_02152021

    Document Title:ASHRAE Guideline 36 Delivered with Tracer Controls / Sales Brochure
    Publication Type:Sales Brochure
    Publication Date:2021-02-15
    maximize system energy efficiency and performance, provide control stability, and allow for real-time fault detection and diagnostics. The current version of the guideline provides sequences specific to Multiple Zone Variable Air Volume (VAV) systems. VAV boxes and Air Handling Units (AHU) utilizing