Search Results: 18-CH94D1-1C-EN

Showing 1,401 - 1,410 of 7,130 results

Display results per page.
  • Media type icon

    PART-SVN27C-EN_08122020

    Document Title:Location of Parts, Compressor Motor Change Out Kit, KIT16366, Model Number: CVHF / Installation Instructions
    Publication Type:Installation
    Publication Date:2020-08-12
    by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. © 2020 Trane Model Number: CVHF August 2020 PART-SVN27C-EN Installation Instructions
  • Media type icon

    TEMP-SVN007A-EN_07102021

    Document Title:Trane Rental Service Start-Up and Shutdown - RSGP0900F5 Generator
    Publication Type:Installation
    Publication Date:2021-07-10
    TEMP-SVN007-EN.book Trane Rental ServiceStart-Up and Shutdown - RSGP0900F5Generator Installation Instructions July 2021 TEMP-SVN007A-EN SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air
  • Media type icon

    PART-PRC010A-EN_05062025

    Document Title:R-410A Scroll Compressor Models CSHN and CSHL 15 to 30 Tons
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2025-05-06
    — 122,144 156,955 198,682 247,460 303,373 334,018 366,451 436,654 130 — — 143,445 182,383 227,952 280,238 308,912 339,271 405,013 140 — — — 165,314 207,441 255,851 282,424 310,575 371,577 150 — — — — 185,401 229,555 253,825 279,556 335,372 Performance Data 18 PART-PRC010A-EN Table 8. Capacity (btu
  • Media type icon

    RLC-SVX09T-EN_10312025

    ) • Dry nitrogen (20 psig max permachine as needed) Pre-Installation 18 RLC-SVX09T-EN Unit Dimensions and WeightsUnit DimensionsFigure 1. RTWD 80 to 140 tons, 60 Hz 10 9 13 14 15 2 1 3 411 5 6 8 7 12 12 A G H C D E F N RM B J L K N J S E( 3 pass evap ) 2 pass evap 3 pass evap ( 3 pass evap ) (3 pass
  • Media type icon

    BAS-SVN085H-EN_06092020

    Document Title:Tracer® UC600 Programmable Controller Order Number: BMUC600AAA0100011, BMUC600USA0100011,BMUC600CCA0100011 (Part number: X13651548)
    Publication Type:Installation
    Publication Date:2020-06-09
    Programmable ControllerOrder Number: BMUC600AAA0100011, BMUC600USA0100011,BMUC600CCA0100011 (Part number: X13651548) X39641178-01 June 2020 BAS-SVN085H-EN 1Warnings, Cautions, and Notices The three types of advisories are defined as follows: WARNINGIndicates a potentially hazardous situation which, if
  • Media type icon

    ACC-SVN188D-EN_08232024

    Document Title:LP Conversion Kit - Foundation™ Packaged Rooftop Units
    Publication Type:Installation
    Publication Date:2024-08-23
    LP Conversion KitFoundation™ Packaged Rooftop Units3 to 5 Tons August 2024 ACC-SVN188D-EN 1 Warnings, Cautions, and NoticesRead this manual thoroughly before operating or servicing this unit. Safety advisories appear throughout this manual as required. Your personal safety and the proper operation
  • Media type icon

    ACC-SVN166E-EN_09152024

    Document Title:High Altitude Conversion Kit Foundation™ Packaged Rooftop Units 15 to 25 Tons
    Publication Type:Installation
    Publication Date:2024-09-15
    position and adjust the setpoint indicator to its highest setting. The burners should light. 17.If required, adjust the unit manifold pressure to the value listed on the unit nameplate.18.Install the access panel. Figure 2. Remove orifices from manifold Installation Instructions High Altitude Conversion
  • Media type icon

    UNT-SVX07Q-EN_06302025

    /heating, 1-row heating 8 UNT-SVX07Q-EN Digit 18 — Main Coil (continued) Q = 2-row cooling/heating, 2-row heatingR = 3-row cooling/heating, 1-row heatingU = Electric heat only, 2 stageV = Electric heat, Low kW, 1 stageW = Steam coilX = 2-row cooling only, Electric heatY = 3-row cooling only
  • Media type icon

    ODR-PSD042A-EN_12132025

    ODR-PSD042A-EN_12132025 December 2025 ODR-PSD042A-EN Heat Pump5TWR6018A1000A5TWR6024A1000A5TWR6030A1000A5TWR6036A1000A5TWR6042A1000A5TWR6048A1000A5TWR6060A1000A Note: Graphics in this document are for representation only.Actual model may differ in appearance. Product and Submittal Data ©2025 Trane
  • Media type icon

    ODR-PSD006A-EN_06102025

    Document Title:Split System Heat Pump 5TWA4
    Publication Type:Product and Submittal Data
    Publication Date:2025-06-10
    appearance. Product and Submittal Data ©2025 Trane ODR-PSD006A-EN CopyrightThis document and the information in it are the property of Trane, and may not be used orreproduced in whole or in part without written permission. Trane reserves the right to revise thispublication at any time, and to make changes to