Search Results: ED*

Showing 1,231 - 1,240 of 1,410 results

Display results per page.
  • Media type icon

    BAS-SVN241A-EN_03212026

    Document Title:Trane® Cell Modem
    Publication Type:Installation
    Publication Date:2026-03-21
    to prevent water ingress; avoid locations near heat sources or where water might collect. 3. Prepare cable entry and sealing.a. Create a cable entry point by removing a knockout or drilling a new hole in the cabinet; a ~1-inch opening is sufficient.b. Deburr all edges thoroughly to prevent cable
  • Media type icon

    AC-SLB012-EN_12202024

    Document Title:PEP Ecopassport®
    Publication Type:Sales Brochure
    Publication Date:2024-12-20
    -EN Drafting rules: “PEP-PCR-ed4-EN-2021 09 06” Supplemented by “PSR-0013-ed3.0-EN-2023 06 06” Verifier accreditation number: VH44 Information and reference documents: www.pep- ecopassport.org Date of issue: 12-2024 Validity period: 5 years Independent verification of the declaration and data in
  • Media type icon

    CLCH-SLB043-EN_02282026

    Document Title:PEP Ecopassport® Product Environmental Profile – Performance Climate Changer® Semi-Custom Air Handling Units (CSAA and PSCA) FEBRUARY 2026 RN TRNE-10004-V0.1.01-EN
    Publication Type:Sales Brochure
    Publication Date:2026-02-28
    -specific-data Registration number: TRNE-10004-V01.01-EN Drafting rules: “PEP-PCR-ed4-EN-2021 09 06” Supplemented by “PSR-0008-ed3.0-EN-2023 10 19” Verifier accreditation number: VH44 Information and reference documents: www.pep- ecopassport.org Date of issue: 2-2026 Validity period: 5 years
  • Media type icon

    CDHF-SVX004E-EN_04112026

    exchangertubing that could lead to in-service tube failures. Eddycurrent tests conducted before a chiller is put into serviceare considered “baseline” eddy current tests, and areintended to establish a reference point to aid in theinterpretation of future eddy current test reports. Many ofthe anomalies that
  • Media type icon

    CDHH-SVX003F-EN_04112026

    every three years. Eddy current tests are intendedto identify defects on or within the walls of heat exchangertubing that could lead to in-service tube failures. Eddycurrent tests conducted before a chiller is put into serviceare considered baseline eddy current tests, and areintended to establish a
  • Media type icon

    CVHE-SVX005E-EN_04112026

    tests are intendedto identify defects on or within the walls of heat exchangertubing that could lead to in-service tube failures. Eddycurrent tests conducted before a chiller is put into serviceare considered “baseline” eddy current tests, and areintended to establish a reference point to aid in
  • Media type icon

    CVHH-SVX003F-EN_04112026

    Document Title:CenTraVac™ Water-cooled Chillers Model CVHH With Symbio™ Controls
    Publication Type:Installation Operation and Maintenance
    Publication Date:2026-04-11
    intendedto identify defects on or within the walls of heat exchangertubing that could lead to in-service tube failures. Eddycurrent tests conducted before a chiller is put into serviceare considered baseline eddy current tests, and areintended to establish a reference point to aid in theinterpretation
  • Media type icon

    VFDB-SVX001E-EN_04112026

    Frame A drive,isolation Transformer and Power Module/LV control will betogether in one crate. For Frame B drive, isolationTransformer and Power Module/LV control will beseparated in two crates.The shipment includes the document /hardware box also:• Testing Reports• Electrical Drawings (EDs) and
  • Media type icon

    BAS-SVX40Q-EN_04152026

    Document Title:Air-Fi® Wireless System
    Publication Type:Installation Operation and Maintenance
    Publication Date:2026-04-15
    link.4. Select the Create Network button. A new network will be displayed.5. Edit the BACnet® Network Number, Network Name, and Network Description if needed. The BACnet® network numbers is provided by default but can be edited using the pencil icon. BACnet® network numbers should not be duplicated.6
  • Media type icon

    UV-PRC007D-EN_04112026

    67.07 44.90 13.35 11.67 DK 48.70 35.47 9.71 12.26 DX CoilsTable 17. R-454B cooling only HUVUnit Size SuctionTemperature EWB (°F) T-Btu/hr(a) S-Btu/hr EDB 72°F EDB 76°F EDB 80°F 075 40 63 18865 12052 15467 18574 45 67 19919 7972 11532 15060 50 71 21029 3638 7170 10878 100 40 63 24820 15965 20784 24543